This project has adopted the [Microsoft Open Source Code of Conduct](https://opensource.microsoft.com/codeofconduct/). For more information see the [Code of Conduct FAQ](https://opensource.microsoft.com/codeofconduct/faq/) or contact [opencode@microsoft.com](mailto:opencode@microsoft.com) with any additional questions or comments
# Azure IoT Edge Modbus Module Preview #
Using this module, developers can build Azure IoT Edge solutions with Modbus TCP connectivity. The Modbus module is an [Azure IoT Edge](https://github.com/Azure/iot-edge) module, capable of reading data from Modbus devices and publishing data to the Azure IoT Hub via the Edge framework. Developers can modify the module tailoring to any scenario.
Using this module, developers can build Azure IoT Edge solutions with Modbus TCP connectivity. The Modbus module is an [Azure IoT Edge](https://github.com/Azure/iot-edge) module, capable of reading data from Modbus devices and publishing data to the Azure IoT Hub via the Edge framework. Developers can modify the module tailoring to any scenario.
![](./doc/diagram.png)
If you are using V1 version of IoT Edge (previously known as Azure IoT Gateway), please use V1 version of this module, all materials can be found in [V1](https://github.com/Azure/iot-gateway-modbus/tree/master/V1) folder.
@ -17,24 +17,31 @@ Refer to [Azure IoT Edge](https://github.com/Azure/azure-iot-edge)
Refer to [Azure IoT Edge](https://github.com/Azure/azure-iot-edge)
## HowTo Run ##
This section will help you download the module from docker hub, and run it with IoT Edge directly.
This section will help you download the prebuilt module image from docker hub, and run it with IoT Edge directly.
1. Setup [Azure IoT Edge](https://github.com/Azure/azure-iot-edge) with compatible version on your machine.
2. Follow [this](https://docs.microsoft.com/en-us/azure/iot-edge/quickstart?branch=release-iot-edge-v2) to deploy a custom IoT Edge module.
3. In the Image field, enter **microsoft/azureiotedge-modbus-tcp:1.0-preview**.
4. You may also want to provide configuration to the module when it starts, paste the configuration in the desired property field. For more about configuration, see [here](https://github.com/Azure/iot-edge-modbus#configuration).
## HowTo Build ##
If you prefer to build your own module, use the following script. Dockerfiles are located under [Docker](https://github.com/Azure/iot-edge-modbus/tree/master/Docker) folder, you should be able to find one for your platform. There are two Docker files in each platform, the one ended with **-auto** will automatically build source code and Docker image. The other one requires you to build source code first and then copy binary to the image. Note: Arm32 auto build doesn't work at this moment, please build it manually.
### -auto ###
1. cd iot-edge-modbus/
2. docker build -t "**name of the docker image**" -f "**path to the auto docker file**" .
### non-auto ###
1. cd iot-edge-modbus/src/
2. dotnet restore
3. dotnet build
4. dotnet publish -f netcoreapp2.0
5. cd ../iot-edge-modbus/
6. docker build --build-arg EXE_DIR=./src/bin/Debug/netcoreapp2.0/publish -t "**name of the docker image**" -f "**path to the docker file**" .
If you prefer to build your own module, use the following script. Dockerfiles are located under [Docker](https://github.com/Azure/iot-edge-modbus/tree/master/Docker) folder, you should be able to find one for your platform. There are two Dockerfiles in each platform, the multi-stage Dockerfile-auto will automatically build source code and Docker image. The other Dockerfile requires you to build source code first and then copy binary to the image.
**Note**: Arm32 multi-stage build doesn't work at this moment, please build it manually.
**Note**: Please replace **PlatForm** in below scripts with the actual platform path you are trying to build.
### Multi-stage build ###
```cmd
>cd iot-edge-modbus/
>docker build -t modbusModule -f Docker/<PlatForm>/Dockerfile-auto .
```
### Manually build ###
The application requires the [.NET Core SDK 2.0](https://www.microsoft.com/net/download/windows).
```cmd
>cd iot-edge-modbus/src/
>dotnet restore
>dotnet build
>dotnet publish -f netcoreapp2.0
>cd ../iot-edge-modbus/
>docker build --build-arg EXE_DIR=./src/bin/Debug/netcoreapp2.0/publish -t modbusModule -f Docker/<PlatForm>/Dockerfile .
```
## Configuration ##
The Modbus module uses module twin as its configuration. Here is a sample configuration for your reference.
@ -83,15 +90,17 @@ The Modbus module uses module twin as its configuration. Here is a sample config
```
Meaning of each field:
* "SlaveConfigs" – Contains one or more Modbus slaves' configuration. In this sample, we have Slave01 and Slave02 two devices:
* "SlaveConfigs" – Contains one or more Modbus slaves' configuration. In this sample, we have "Slave01" and "Slave02" two devices:
* "Interval" – Interval between each push to IoT Hub in millisecond
* "Slave01", "Slave02" - User defined names for each Modbus slave, cannot have duplicates
* "SlaveConnection" – IPV4 address of the Modbus slave
* "HwId" – Unique Id for each Modbus slave (user defined)
* "Operations" – Contains one or more Modbus read requests. In this sample, we have Op01 and Op02 two read requests in both Slave01 and Slave02:
* "Operations" – Contains one or more Modbus read requests. In this sample, we have "Op01" and "Op02" two read requests in both Slave01 and Slave02:
* "UnitId" – The unit id to be read
* "StartAddress" – The starting address of Modbus read request, currently supports both 5-digit and 6-digit [format](https://en.wikipedia.org/wiki/Modbus#Coil.2C_discrete_input.2C_input_register.2C_holding_register_numbers_and_addresses)
* "Count" – Number of registers/bits to be read
* "DisplayName" – Alternative name for the #StartAddress register(s)(user defined)
* "DisplayName" – Alternative name for the "StartAddress" register(s)(user defined)
* "Op01", "Op02" - User defined names for each read request, cannot have duplicates under the same "SlaveConfig"
For more about Modbus, please refer to the [Wiki](https://en.wikipedia.org/wiki/Modbus) link.
@ -127,4 +136,5 @@ The command should have a property "command-type" with value "ModbusWrite". Also
```
## Debug ##
There is a flag **IOT_EDGE** at the first line in Program.cs, which can be turn off to debug the Modbus module in console mode. Note: running in console mode means none of the IoT Edge features is available. This mode is only to debug non edge-related functions. Running console mode requires IoT device connection string being inserted as a environment variable named **EdgeHubConnectionString**, and a local configuration file **iot-edge-modbus.json** since module twin is not available.
There is a flag **IOT_EDGE** at the first line in Program.cs, which can be turn off to debug the Modbus module in console mode. Running console mode requires IoT device connection string being inserted as a environment variable named **EdgeHubConnectionString**, and a local configuration file **iot-edge-modbus.json** since module twin is not available.
**Note**: running in console mode means none of the IoT Edge features is available. This mode is only to debug non edge-related functions.