зеркало из https://github.com/microsoft/MSLab.git
NetATC revamped
This commit is contained in:
Родитель
caa00eb21f
Коммит
95dcb341c8
|
@ -39,7 +39,7 @@
|
|||
$WindowsUpdate="Recommended" #Can be "All","Recommended" or "None"
|
||||
|
||||
#Dell updates
|
||||
$DellUpdates=$true
|
||||
$DellUpdates=$false
|
||||
|
||||
#Witness type
|
||||
$WitnessType="FileShare" #or Cloud
|
||||
|
@ -164,7 +164,7 @@
|
|||
}
|
||||
}
|
||||
#define and install other features
|
||||
$features="Failover-Clustering","RSAT-Clustering-PowerShell","Hyper-V-PowerShell","NetworkATC","NetworkHUD","Data-Center-Bridging","Bitlocker","RSAT-Feature-Tools-BitLocker","Storage-Replica","RSAT-Storage-Replica","FS-Data-Deduplication","System-Insights","RSAT-System-Insights"
|
||||
$features="Failover-Clustering","RSAT-Clustering-PowerShell","Hyper-V-PowerShell","NetworkATC","NetworkHUD","Data-Center-Bridging","FS-SMBBW","Bitlocker","RSAT-Feature-Tools-BitLocker","Storage-Replica","RSAT-Storage-Replica","FS-Data-Deduplication","System-Insights","RSAT-System-Insights"
|
||||
Invoke-Command -ComputerName $servers -ScriptBlock {Install-WindowsFeature -Name $using:features}
|
||||
#endregion
|
||||
|
||||
|
@ -610,70 +610,67 @@
|
|||
|
||||
#region Configure networking with NetATC https://techcommunity.microsoft.com/t5/networking-blog/network-atc-what-s-coming-in-azure-stack-hci-22h2/ba-p/3598442
|
||||
if ($NetATC){
|
||||
#make sure NetATC and other required features are installed on servers
|
||||
#make sure NetATC,FS-SMBBW and other required features are installed on servers
|
||||
Invoke-Command -ComputerName $Servers -ScriptBlock {
|
||||
Install-WindowsFeature -Name NetworkATC,Data-Center-Bridging,RSAT-Clustering-PowerShell,RSAT-Hyper-V-Tools
|
||||
Install-WindowsFeature -Name NetworkATC,Data-Center-Bridging,RSAT-Clustering-PowerShell,RSAT-Hyper-V-Tools,FS-SMBBW
|
||||
}
|
||||
|
||||
#netatc CredSSP (hopefully CredSSP and "-ClusterName LocalHost" will go away in 11c)
|
||||
# Temporarily enable CredSSP delegation to avoid double-hop issue
|
||||
$CredSSPUserName="corp\LabAdmin"
|
||||
$CredSSPPassword="LS1setup!"
|
||||
foreach ($Server in $Servers){
|
||||
Enable-WSManCredSSP -Role "Client" -DelegateComputer $Server -Force
|
||||
}
|
||||
Invoke-Command -ComputerName $Servers -ScriptBlock { Enable-WSManCredSSP Server -Force }
|
||||
#since ATC is not available on managment machine, copy PowerShell module over to management machine from cluster. However global intents will not be automatically added as in C:\Windows\System32\WindowsPowerShell\v1.0\Modules\NetworkATC\NetWorkATC.psm1 is being checked if NetATC feature is installed [FabricManager.FeatureStaging]::Feature_NetworkATC_IsEnabled()
|
||||
$session=New-PSSession -ComputerName $ClusterName
|
||||
$items="C:\Windows\System32\WindowsPowerShell\v1.0\Modules\NetworkATC","C:\Windows\System32\NetworkAtc.Driver.dll","C:\Windows\System32\Newtonsoft.Json.dll","C:\Windows\System32\NetworkAtcFeatureStaging.dll"
|
||||
foreach ($item in $items){
|
||||
Copy-Item -FromSession $session -Path $item -Destination $item -Recurse -Force
|
||||
}
|
||||
|
||||
$SecureStringPassword = ConvertTo-SecureString $CredSSPPassword -AsPlainText -Force
|
||||
$Credentials = New-Object System.Management.Automation.PSCredential ($CredSSPUserName, $SecureStringPassword)
|
||||
#if virtual environment, then skip RDMA config
|
||||
if ((Get-CimInstance -ClassName win32_computersystem -CimSession $servers[0]).Model -eq "Virtual Machine"){
|
||||
Import-Module NetworkATC
|
||||
#virtual environment (skipping RDMA config)
|
||||
$AdapterOverride = New-NetIntentAdapterPropertyOverrides
|
||||
$AdapterOverride.NetworkDirect = 0
|
||||
Add-NetIntent -ClusterName $ClusterName -Name ConvergedIntent -Management -Compute -Storage -AdapterName "Ethernet","Ethernet 2" -AdapterPropertyOverrides $AdapterOverride -Verbose #-StorageVlans 1,2
|
||||
}else{
|
||||
#on real hardware you can configure RDMA
|
||||
#grab fastest adapters names (assuming that we are deploying converged intent with just Mellanox or Intel E810)
|
||||
$FastestLinkSpeed=(get-netadapter -CimSession $Servers | Where-Object {$_.Status -eq "up" -and $_.HardwareInterface -eq $True}).Speed | Sort-Object -Descending | Select-Object -First 1
|
||||
#grab adapters
|
||||
$AdapterNames=(Get-NetAdapter -CimSession $ClusterName | Where-Object {$_.Status -eq "up" -and $_.HardwareInterface -eq $True} | where-object Speed -eq $FastestLinkSpeed | Sort-Object Name).Name
|
||||
#$AdapterNames="SLOT 3 Port 1","SLOT 3 Port 2"
|
||||
Import-Module NetworkATC
|
||||
Add-NetIntent -ClusterName $ClusterName -Name ConvergedIntent -Management -Compute -Storage -AdapterName $using:AdapterNames -Verbose #-StorageVlans 1,2
|
||||
}
|
||||
|
||||
if ((Get-CimInstance -ClassName win32_computersystem -CimSession $servers[0]).Model -eq "Virtual Machine"){
|
||||
Invoke-Command -ComputerName $servers[0] -Credential $Credentials -Authentication Credssp -ScriptBlock {
|
||||
Import-Module NetworkATC
|
||||
#virtual environment (skipping RDMA config)
|
||||
$AdapterOverride = New-NetIntentAdapterPropertyOverrides
|
||||
$AdapterOverride.NetworkDirect = 0
|
||||
Add-NetIntent -ClusterName LocalHost -Name ConvergedIntent -Management -Compute -Storage -AdapterName "Ethernet","Ethernet 2" -AdapterPropertyOverrides $AdapterOverride -Verbose #-StorageVlans 1,2
|
||||
}
|
||||
}else{
|
||||
#real hardware
|
||||
#grab fastest adapters names (assuming that we are deploying converged intent with just Mellanox or Intel E810)
|
||||
$FastestLinkSpeed=(get-netadapter -CimSession $Servers | Where-Object {$_.Status -eq "up" -and $_.HardwareInterface -eq $True}).Speed | Sort-Object -Descending | Select-Object -First 1
|
||||
#grab adapters
|
||||
$AdapterNames=(Get-NetAdapter -CimSession $ClusterName | Where-Object {$_.Status -eq "up" -and $_.HardwareInterface -eq $True} | where-object Speed -eq $FastestLinkSpeed | Sort-Object Name).Name
|
||||
#$AdapterNames="SLOT 3 Port 1","SLOT 3 Port 2"
|
||||
Invoke-Command -ComputerName $servers[0] -Credential $Credentials -Authentication Credssp -ScriptBlock {
|
||||
Import-Module NetworkATC
|
||||
Add-NetIntent -ClusterName LocalHost -Name ConvergedIntent -Management -Compute -Storage -AdapterName $using:AdapterNames -Verbose #-StorageVlans 1,2
|
||||
#Add default global intent
|
||||
#since when configuring from Management machine there is a test [FabricManager.FeatureStaging]::Feature_NetworkATC_IsEnabled() to make global intents available, it will not be configured, so it has to be configured manually with invoke command
|
||||
Invoke-Command -ComputerName $servers[0] -ScriptBlock {
|
||||
Import-Module NetworkATC
|
||||
$overrides=New-NetIntentGlobalClusterOverrides
|
||||
#add empty intent
|
||||
Add-NetIntent -GlobalClusterOverrides $overrides
|
||||
}
|
||||
|
||||
#check
|
||||
Start-Sleep 20 #let intent propagate a bit
|
||||
Write-Output "applying intent"
|
||||
do {
|
||||
$status=Invoke-Command -ComputerName $servers[0] -ScriptBlock {Get-NetIntentStatus}
|
||||
Write-Host "." -NoNewline
|
||||
Start-Sleep 5
|
||||
} while ($status.ConfigurationStatus -contains "Provisioning" -or $status.ConfigurationStatus -contains "Retrying")
|
||||
|
||||
#remove if necessary
|
||||
<#
|
||||
Invoke-Command -ComputerName $servers[0] -ScriptBlock {
|
||||
$intents = Get-NetIntent
|
||||
foreach ($intent in $intents){
|
||||
Remove-NetIntent -Name $intent.IntentName
|
||||
}
|
||||
}
|
||||
|
||||
#check
|
||||
Start-Sleep 20 #let intent propagate a bit
|
||||
Write-Output "applying intent"
|
||||
do {
|
||||
$status=Invoke-Command -ComputerName $servers[0] -ScriptBlock {Get-NetIntentStatus -ClusterName LocalHost}
|
||||
Write-Host "." -NoNewline
|
||||
Start-Sleep 5
|
||||
} while ($status.ConfigurationStatus -contains "Provisioning" -or $status.ConfigurationStatus -contains "Retrying")
|
||||
|
||||
#remove if necessary
|
||||
<#
|
||||
Invoke-Command -ComputerName $servers[0] -ScriptBlock {
|
||||
$intents = Get-NetIntent -ClusterName localhost
|
||||
foreach ($intent in $intents){
|
||||
Remove-NetIntent -Name $intent.IntentName -ClusterName Localhost
|
||||
}
|
||||
}
|
||||
#>
|
||||
#>
|
||||
|
||||
#if deploying in VMs, some nodes might fail (quarantined state) and even CNO can go to offline ... go to cluadmin and fix
|
||||
#Get-ClusterNode -Cluster $ClusterName | Where-Object State -eq down | Start-ClusterNode -ClearQuarantine
|
||||
|
||||
# Disable CredSSP
|
||||
Disable-WSManCredSSP -Role Client
|
||||
Invoke-Command -ComputerName $servers -ScriptBlock { Disable-WSManCredSSP Server }
|
||||
|
||||
<#
|
||||
#since ATC is not available on managment machine, you can copy PowerShell module over. However not everything works as in C:\Windows\System32\WindowsPowerShell\v1.0\Modules\NetworkATC\NetWorkATC.psm1 is often being checked if NetATC feature is installed [FabricManager.FeatureStaging]::Feature_NetworkATC_IsEnabled()
|
||||
$session=New-PSSession -ComputerName $ClusterName
|
||||
|
@ -690,60 +687,26 @@ if ($NetATC){
|
|||
#make sure NetworkHUD feature is installed and started on servers
|
||||
Invoke-Command -ComputerName $Servers -ScriptBlock {
|
||||
Install-WindowsFeature -Name "NetworkHUD"
|
||||
Set-Service -Name NetworkHUD -StartupType Automatic
|
||||
Start-Service -Name NetworkHUD
|
||||
#make sure service is started and running (it is)
|
||||
#Set-Service -Name NetworkHUD -StartupType Automatic
|
||||
#Start-Service -Name NetworkHUD
|
||||
}
|
||||
}
|
||||
#endregion
|
||||
|
||||
#region configure what was/was not configured with NetATC
|
||||
if ($NetATC){
|
||||
#disable unused adapters
|
||||
Get-Netadapter -CimSession $Servers | Where-Object Status -ne "Up" | Disable-NetAdapter -Confirm:0
|
||||
#region Configure what NetATC is not configuring
|
||||
#disable unused adapters
|
||||
Get-Netadapter -CimSession $Servers | Where-Object Status -ne "Up" | Disable-NetAdapter -Confirm:0
|
||||
|
||||
#Rename and Configure USB NICs (iDRAC Network)
|
||||
$USBNics=get-netadapter -CimSession $Servers -InterfaceDescription "Remote NDIS Compatible Device" -ErrorAction Ignore
|
||||
if ($USBNics){
|
||||
$Network=(Get-ClusterNetworkInterface -Cluster $ClusterName | Where-Object Adapter -eq "Remote NDIS Compatible Device").Network | Select-Object -Unique
|
||||
$Network.Name="iDRAC"
|
||||
$Network.Role="none"
|
||||
}
|
||||
|
||||
#Check what networks were excluded from Live Migration
|
||||
$Networks=(Get-ClusterResourceType -Cluster $clustername -Name "Virtual Machine" | Get-ClusterParameter -Name MigrationExcludeNetworks).Value -split ";"
|
||||
foreach ($Network in $Networks){Get-ClusterNetwork -Cluster $ClusterName | Where-Object ID -Match $Network}
|
||||
|
||||
#check Live Migration option
|
||||
Get-VMHost -CimSession $Servers | Select-Object *Migration*
|
||||
|
||||
#Check LiveMigrationPerf option and Limit
|
||||
Get-Cluster -Name $ClusterName | Select-Object *SMB*
|
||||
|
||||
#check VLAN settings
|
||||
Get-VMNetworkAdapterIsolation -CimSession $Servers -ManagementOS
|
||||
|
||||
#adjust if necessary (Global cluster overrides may/may not work as there is a bug in 22h2 importing this piece of powershell module - [FabricManager.FeatureStaging]::Feature_NetworkATC_IsEnabled() sometimes work, sometimes not. Need to explore more)
|
||||
Invoke-Command -ComputerName $Servers[0] -ScriptBlock {
|
||||
$overrides=New-NetIntentGlobalClusterOverrides
|
||||
$overrides.MaximumVirtualMachineMigrations=4
|
||||
$overrides.MaximumSMBMigrationBandwidthInGbps=20
|
||||
$overrides.VirtualMachineMigrationPerformanceOption="SMB"
|
||||
Set-NetIntent -ClusterName LocalHost -GlobalClusterOverrides $overrides
|
||||
}
|
||||
|
||||
Start-Sleep 20 #let intent propagate a bit
|
||||
Write-Output "applying overrides intent"
|
||||
do {
|
||||
$status=Invoke-Command -ComputerName $Servers[0] -ScriptBlock {Get-NetIntentStatus -Globaloverrides -ClusterName LocalHost}
|
||||
Write-Host "." -NoNewline
|
||||
Start-Sleep 5
|
||||
} while ($status.ConfigurationStatus -contains "Provisioning" -or $status.ConfigurationStatus -contains "Retrying")
|
||||
|
||||
#check Live Migration option
|
||||
Get-VMHost -CimSession $Servers | Select-Object *Migration*
|
||||
|
||||
#Check LiveMigrationPerf option and Limit (Need more research on how the bandwidth works as it seems unchanged)
|
||||
Get-Cluster -Name $ClusterName | Select-Object *SMB*
|
||||
#Rename and Configure USB NICs (iDRAC Network)
|
||||
$USBNics=get-netadapter -CimSession $Servers -InterfaceDescription "Remote NDIS Compatible Device" -ErrorAction Ignore
|
||||
if ($USBNics){
|
||||
$Network=(Get-ClusterNetworkInterface -Cluster $ClusterName | Where-Object Adapter -eq "Remote NDIS Compatible Device").Network | Select-Object -Unique
|
||||
$Network.Name="iDRAC"
|
||||
$Network.Role="none"
|
||||
}
|
||||
|
||||
#Configure dcbxmode to be host in charge (default is firmware in charge) on mellanox adapters (Dell recommendation)
|
||||
#Caution: This disconnects adapters!
|
||||
|
@ -752,15 +715,74 @@ if ($NetATC){
|
|||
Set-NetAdapterAdvancedProperty -CimSession $Servers -InterfaceDescription Mellanox* -DisplayName 'Dcbxmode' -DisplayValue 'Host in charge'
|
||||
}
|
||||
}
|
||||
#endregion
|
||||
|
||||
#Configure SMB Bandwidth Limits for Live Migration https://techcommunity.microsoft.com/t5/Failover-Clustering/Optimizing-Hyper-V-Live-Migrations-on-an-Hyperconverged/ba-p/396609
|
||||
#note: this should be normally configured with NetATC... docs needed https://techcommunity.microsoft.com/t5/networking-blog/network-atc-what-s-coming-in-azure-stack-hci-22h2/ba-p/3598442
|
||||
#install feature
|
||||
Invoke-Command -ComputerName $servers -ScriptBlock {Install-WindowsFeature -Name "FS-SMBBW"}
|
||||
#Calculate 40% of capacity of NICs in vSwitch (considering 2 NICs, if 1 fails, it will not consume all bandwith, therefore 40%)
|
||||
$Adapters=(Get-VMSwitch -CimSession $Servers[0]).NetAdapterInterfaceDescriptions
|
||||
$BytesPerSecond=((Get-NetAdapter -CimSession $Servers[0] -InterfaceDescription $adapters).TransmitLinkSpeed | Measure-Object -Sum).Sum/8
|
||||
Set-SmbBandwidthLimit -Category LiveMigration -BytesPerSecond ($BytesPerSecond*0.4) -CimSession $Servers
|
||||
#region Check settings before applying NetATC
|
||||
#Check what networks were excluded from Live Migration
|
||||
$Networks=(Get-ClusterResourceType -Cluster $clustername -Name "Virtual Machine" | Get-ClusterParameter -Name MigrationExcludeNetworks).Value -split ";"
|
||||
foreach ($Network in $Networks){Get-ClusterNetwork -Cluster $ClusterName | Where-Object ID -Match $Network}
|
||||
|
||||
#check Live Migration option
|
||||
Get-VMHost -CimSession $Servers | Select-Object *Migration*
|
||||
|
||||
#Check smbbandwith limit cluster settings
|
||||
Get-Cluster -Name $ClusterName | Select-Object *SMB*
|
||||
|
||||
#check SMBBandwidthLimit settings
|
||||
Get-SmbBandwidthLimit -CimSession $Servers
|
||||
|
||||
#check VLAN settings
|
||||
Get-VMNetworkAdapterIsolation -CimSession $Servers -ManagementOS
|
||||
#endregion
|
||||
|
||||
#region Adjust NetATC global overrides
|
||||
Invoke-Command -ComputerName $Servers[0] -ScriptBlock {
|
||||
Import-Module NetworkATC
|
||||
$overrides=New-NetIntentGlobalClusterOverrides
|
||||
$overrides.MaximumVirtualMachineMigrations=4
|
||||
$overrides.MaximumSMBMigrationBandwidthInGbps=20 #assuming you have 25Gbps NICs
|
||||
$overrides.VirtualMachineMigrationPerformanceOption="SMB"
|
||||
Set-NetIntent -GlobalClusterOverrides $overrides
|
||||
}
|
||||
|
||||
Start-Sleep 20 #let intent propagate a bit
|
||||
Write-Output "applying overrides intent"
|
||||
do {
|
||||
$status=Invoke-Command -ComputerName $Servers[0] -ScriptBlock {Get-NetIntentStatus -Globaloverrides}
|
||||
Write-Host "." -NoNewline
|
||||
Start-Sleep 5
|
||||
} while ($status.ConfigurationStatus -contains "Provisioning" -or $status.ConfigurationStatus -contains "Retrying")
|
||||
#endregion
|
||||
|
||||
#region verify settings again
|
||||
#Check Cluster Global overrides
|
||||
Invoke-Command -ComputerName $ClusterName -ScriptBlock {
|
||||
Import-Module NetworkATC
|
||||
$GlobalOverrides=Get-Netintent -GlobalOverrides
|
||||
$GlobalOverrides.ClusterOverride
|
||||
}
|
||||
|
||||
#check Live Migration option
|
||||
Get-VMHost -CimSession $Servers | Select-Object *Migration*
|
||||
|
||||
#Check LiveMigrationPerf option and Limit (it was disabled)
|
||||
Get-Cluster -Name $ClusterName | Select-Object *SMB*
|
||||
|
||||
#check SMBBandwidthLimit settings (is now 20Gbps = 2.5GBps = 2500000000)
|
||||
Get-SmbBandwidthLimit -CimSession $Servers
|
||||
|
||||
#endregion
|
||||
|
||||
#remove net intent global overrides if necessary
|
||||
<#
|
||||
Invoke-Command -ComputerName $servers[0] -ScriptBlock {
|
||||
Import-Module NetworkATC
|
||||
Remove-NetIntent -GlobalOverrides
|
||||
$overrides=New-NetIntentGlobalClusterOverrides
|
||||
#add empty intent
|
||||
Add-NetIntent -GlobalClusterOverrides $overrides
|
||||
}
|
||||
#>
|
||||
}
|
||||
#endregion
|
||||
|
||||
|
@ -1178,7 +1200,7 @@ if ((Get-CimInstance -ClassName win32_computersystem -CimSession $Servers[0]).Ma
|
|||
$ComputersInfo = Invoke-Command -ComputerName $servers -ScriptBlock {
|
||||
Get-ItemProperty -Path $using:RegistryPath
|
||||
}
|
||||
$ComputersInfo | Select-Object PSComputerName,CurrentBuildNumber,UBR
|
||||
$ComputersInfo | Select-Object PSComputerName,ProductName,DisplayVersion,UBR
|
||||
|
||||
#check last driver update status
|
||||
Invoke-Command -ComputerName $Servers -ScriptBlock {
|
||||
|
|
|
@ -1,4 +1,4 @@
|
|||
## Notes:
|
||||
* Notice AllowedVLANs in labconfig (to simulate VLANs configuration in NetATC)
|
||||
* CreateParentDisk will create VHD with name AzSHCI**21**H2_G2.vhdx even with 22h2 media. Please rename VHDx manually
|
||||
* Make sure you use latest 21H2 cumulative update (at least version 20348.1070 - september preview CU) as there are new cluster parameters (not yet used in lab), but it might be useful
|
||||
* Make sure you use latest 22H2 cumulative update (at least version 20348.1070 - september preview CU) as there are new cluster parameters (not yet used in lab), but it might be useful
|
||||
|
|
Загрузка…