@ -39,7 +39,7 @@
$WindowsUpdate="Recommended" #Can be "All","Recommended" or "None"
#Dell updates
$DellUpdates=$true
$DellUpdates=$false
#Witness type
$WitnessType="FileShare" #or Cloud
@ -164,7 +164,7 @@
}
}
#define and install other features
$features="Failover-Clustering","RSAT-Clustering-PowerShell","Hyper-V-PowerShell","NetworkATC","NetworkHUD","Data-Center-Bridging","Bitlocker","RSAT-Feature-Tools-BitLocker","Storage-Replica","RSAT-Storage-Replica","FS-Data-Deduplication","System-Insights","RSAT-System-Insights"
$features="Failover-Clustering","RSAT-Clustering-PowerShell","Hyper-V-PowerShell","NetworkATC","NetworkHUD","Data-Center-Bridging","FS-SMBBW","Bitlocker","RSAT-Feature-Tools-BitLocker","Storage-Replica","RSAT-Storage-Replica","FS-Data-Deduplication","System-Insights","RSAT-System-Insights"
Invoke-Command -ComputerName $servers -ScriptBlock {Install-WindowsFeature -Name $using:features}
#endregion
@ -610,70 +610,67 @@
#region Configure networking with NetATC https://techcommunity.microsoft.com/t5/networking-blog/network-atc-what-s-coming-in-azure-stack-hci-22h2/ba-p/3598442
if ($NetATC){
#make sure NetATC and other required features are installed on servers
#make sure NetATC,FS-SMBBW and other required features are installed on servers
Invoke-Command -ComputerName $Servers -ScriptBlock {
Install-WindowsFeature -Name NetworkATC,Data-Center-Bridging,RSAT-Clustering-PowerShell,RSAT-Hyper-V-Tools
Install-WindowsFeature -Name NetworkATC,Data-Center-Bridging,RSAT-Clustering-PowerShell,RSAT-Hyper-V-Tools,FS-SMBBW
}
#netatc CredSSP (hopefully CredSSP and "-ClusterName LocalHost" will go away in 11c)
# Temporarily enable CredSSP delegation to avoid double-hop issue
$CredSSPUserName="corp\LabAdmin"
$CredSSPPassword="LS1setup!"
foreach ($Server in $Servers){
Enable-WSManCredSSP -Role "Client" -DelegateComputer $Server -Force
}
Invoke-Command -ComputerName $Servers -ScriptBlock { Enable-WSManCredSSP Server -Force }
#since ATC is not available on managment machine, copy PowerShell module over to management machine from cluster. However global intents will not be automatically added as in C:\Windows\System32\WindowsPowerShell\v1.0\Modules\NetworkATC\NetWorkATC.psm1 is being checked if NetATC feature is installed [FabricManager.FeatureStaging]::Feature_NetworkATC_IsEnabled()
$session=New-PSSession -ComputerName $ClusterName
$items="C:\Windows\System32\WindowsPowerShell\v1.0\Modules\NetworkATC","C:\Windows\System32\NetworkAtc.Driver.dll","C:\Windows\System32\Newtonsoft.Json.dll","C:\Windows\System32\NetworkAtcFeatureStaging.dll"
foreach ($item in $items){
Copy-Item -FromSession $session -Path $item -Destination $item -Recurse -Force
}
$SecureStringPassword = ConvertTo-SecureString $CredSSPPassword -AsPlainText -Force
$Credentials = New-Object System.Management.Automation.PSCredential ($CredSSPUserName, $SecureStringPassword)
#if virtual environment, then skip RDMA config
if ((Get-CimInstance -ClassName win32_computersystem -CimSession $servers[0]).Model -eq "Virtual Machine"){
Import-Module NetworkATC
#virtual environment (skipping RDMA config)
$AdapterOverride = New-NetIntentAdapterPropertyOverrides
$AdapterOverride.NetworkDirect = 0
Add-NetIntent -ClusterName $ClusterName -Name ConvergedIntent -Management -Compute -Storage -AdapterName "Ethernet","Ethernet 2" -AdapterPropertyOverrides $AdapterOverride -Verbose #-StorageVlans 1,2
}else{
#on real hardware you can configure RDMA
#grab fastest adapters names (assuming that we are deploying converged intent with just Mellanox or Intel E810)
$FastestLinkSpeed=(get-netadapter -CimSession $Servers | Where-Object {$_.Status -eq "up" -and $_.HardwareInterface -eq $True}).Speed | Sort-Object -Descending | Select-Object -First 1
#grab adapters
$AdapterNames=(Get-NetAdapter -CimSession $ClusterName | Where-Object {$_.Status -eq "up" -and $_.HardwareInterface -eq $True} | where-object Speed -eq $FastestLinkSpeed | Sort-Object Name).Name
#$AdapterNames="SLOT 3 Port 1","SLOT 3 Port 2"
Import-Module NetworkATC
Add-NetIntent -ClusterName $ClusterName -Name ConvergedIntent -Management -Compute -Storage -AdapterName $using:AdapterNames -Verbose #-StorageVlans 1,2
}
if ((Get-CimInstance -ClassName win32_computersystem -CimSession $servers[0]).Model -eq "Virtual Machine"){
Invoke-Command -ComputerName $servers[0] -Credential $Credentials -Authentication Credssp -ScriptBlock {
Import-Module NetworkATC
#virtual environment (skipping RDMA config)
$AdapterOverride = New-NetIntentAdapterPropertyOverrides
$AdapterOverride.NetworkDirect = 0
Add-NetIntent -ClusterName LocalHost -Name ConvergedIntent -Management -Compute -Storage -AdapterName "Ethernet","Ethernet 2" -AdapterPropertyOverrides $AdapterOverride -Verbose #-StorageVlans 1,2
}
}else{
#real hardware
#grab fastest adapters names (assuming that we are deploying converged intent with just Mellanox or Intel E810)
$FastestLinkSpeed=(get-netadapter -CimSession $Servers | Where-Object {$_.Status -eq "up" -and $_.HardwareInterface -eq $True}).Speed | Sort-Object -Descending | Select-Object -First 1
#grab adapters
$AdapterNames=(Get-NetAdapter -CimSession $ClusterName | Where-Object {$_.Status -eq "up" -and $_.HardwareInterface -eq $True} | where-object Speed -eq $FastestLinkSpeed | Sort-Object Name).Name
#$AdapterNames="SLOT 3 Port 1","SLOT 3 Port 2"
Invoke-Command -ComputerName $servers[0] -Credential $Credentials -Authentication Credssp -ScriptBlock {
Import-Module NetworkATC
Add-NetIntent -ClusterName LocalHost -Name ConvergedIntent -Management -Compute -Storage -AdapterName $using:AdapterNames -Verbose #-StorageVlans 1,2
#Add default global intent
#since when configuring from Management machine there is a test [FabricManager.FeatureStaging]::Feature_NetworkATC_IsEnabled() to make global intents available, it will not be configured, so it has to be configured manually with invoke command
Invoke-Command -ComputerName $servers[0] -ScriptBlock {
Import-Module NetworkATC
$overrides=New-NetIntentGlobalClusterOverrides
#add empty intent
Add-NetIntent -GlobalClusterOverrides $overrides
}
#check
Start-Sleep 20 #let intent propagate a bit
Write-Output "applying intent"
do {
$status=Invoke-Command -ComputerName $servers[0] -ScriptBlock {Get-NetIntentStatus}
Write-Host "." -NoNewline
Start-Sleep 5
} while ($status.ConfigurationStatus -contains "Provisioning" -or $status.ConfigurationStatus -contains "Retrying")
#remove if necessary
<#
Invoke-Command -ComputerName $servers[0] -ScriptBlock {
$intents = Get-NetIntent
foreach ($intent in $intents){
Remove-NetIntent -Name $intent.IntentName
}
}
#check
Start-Sleep 20 #let intent propagate a bit
Write-Output "applying intent"
do {
$status=Invoke-Command -ComputerName $servers[0] -ScriptBlock {Get-NetIntentStatus -ClusterName LocalHost}
Write-Host "." -NoNewline
Start-Sleep 5
} while ($status.ConfigurationStatus -contains "Provisioning" -or $status.ConfigurationStatus -contains "Retrying")
#remove if necessary
<#
Invoke-Command -ComputerName $servers[0] -ScriptBlock {
$intents = Get-NetIntent -ClusterName localhost
foreach ($intent in $intents){
Remove-NetIntent -Name $intent.IntentName -ClusterName Localhost
}
}
#>
#>
#if deploying in VMs, some nodes might fail (quarantined state) and even CNO can go to offline ... go to cluadmin and fix
#Get-ClusterNode -Cluster $ClusterName | Where-Object State -eq down | Start-ClusterNode -ClearQuarantine
# Disable CredSSP
Disable-WSManCredSSP -Role Client
Invoke-Command -ComputerName $servers -ScriptBlock { Disable-WSManCredSSP Server }
<#
#since ATC is not available on managment machine, you can copy PowerShell module over. However not everything works as in C:\Windows\System32\WindowsPowerShell\v1.0\Modules\NetworkATC\NetWorkATC.psm1 is often being checked if NetATC feature is installed [FabricManager.FeatureStaging]::Feature_NetworkATC_IsEnabled()
$session=New-PSSession -ComputerName $ClusterName
@ -690,60 +687,26 @@ if ($NetATC){
#make sure NetworkHUD feature is installed and started on servers
Invoke-Command -ComputerName $Servers -ScriptBlock {
Install-WindowsFeature -Name "NetworkHUD"
Set-Service -Name NetworkHUD -StartupType Automatic
Start-Service -Name NetworkHUD
#make sure service is started and running (it is)
#Set-Service -Name NetworkHUD -StartupType Automatic
#Start-Service -Name NetworkHUD
}
}
#endregion
#region configure what was/was not configured with NetATC
if ($NetATC){
#disable unused adapters
Get-Netadapter -CimSession $Servers | Where-Object Status -ne "Up" | Disable-NetAdapter -Confirm:0
#region Configure what NetATC is not configuring
#disable unused adapters
Get-Netadapter -CimSession $Servers | Where-Object Status -ne "Up" | Disable-NetAdapter -Confirm:0
#Rename and Configure USB NICs (iDRAC Network)
$USBNics=get-netadapter -CimSession $Servers -InterfaceDescription "Remote NDIS Compatible Device" -ErrorAction Ignore
if ($USBNics){
$Network=(Get-ClusterNetworkInterface -Cluster $ClusterName | Where-Object Adapter -eq "Remote NDIS Compatible Device").Network | Select-Object -Unique
$Network.Name="iDRAC"
$Network.Role="none"
}
#Check what networks were excluded from Live Migration
$Networks=(Get-ClusterResourceType -Cluster $clustername -Name "Virtual Machine" | Get-ClusterParameter -Name MigrationExcludeNetworks).Value -split ";"
foreach ($Network in $Networks){Get-ClusterNetwork -Cluster $ClusterName | Where-Object ID -Match $Network}
#check Live Migration option
Get-VMHost -CimSession $Servers | Select-Object *Migration*
#Check LiveMigrationPerf option and Limit
Get-Cluster -Name $ClusterName | Select-Object *SMB*
#check VLAN settings
Get-VMNetworkAdapterIsolation -CimSession $Servers -ManagementOS
#adjust if necessary (Global cluster overrides may/may not work as there is a bug in 22h2 importing this piece of powershell module - [FabricManager.FeatureStaging]::Feature_NetworkATC_IsEnabled() sometimes work, sometimes not. Need to explore more)
Invoke-Command -ComputerName $Servers[0] -ScriptBlock {
$overrides=New-NetIntentGlobalClusterOverrides
$overrides.MaximumVirtualMachineMigrations=4
$overrides.MaximumSMBMigrationBandwidthInGbps=20
$overrides.VirtualMachineMigrationPerformanceOption="SMB"
Set-NetIntent -ClusterName LocalHost -GlobalClusterOverrides $overrides
}
Start-Sleep 20 #let intent propagate a bit
Write-Output "applying overrides intent"
do {
$status=Invoke-Command -ComputerName $Servers[0] -ScriptBlock {Get-NetIntentStatus -Globaloverrides -ClusterName LocalHost}
Write-Host "." -NoNewline
Start-Sleep 5
} while ($status.ConfigurationStatus -contains "Provisioning" -or $status.ConfigurationStatus -contains "Retrying")
#check Live Migration option
Get-VMHost -CimSession $Servers | Select-Object *Migration*
#Check LiveMigrationPerf option and Limit (Need more research on how the bandwidth works as it seems unchanged)
Get-Cluster -Name $ClusterName | Select-Object *SMB*
#Rename and Configure USB NICs (iDRAC Network)
$USBNics=get-netadapter -CimSession $Servers -InterfaceDescription "Remote NDIS Compatible Device" -ErrorAction Ignore
if ($USBNics){
$Network=(Get-ClusterNetworkInterface -Cluster $ClusterName | Where-Object Adapter -eq "Remote NDIS Compatible Device").Network | Select-Object -Unique
$Network.Name="iDRAC"
$Network.Role="none"
}
#Configure dcbxmode to be host in charge (default is firmware in charge) on mellanox adapters (Dell recommendation)
#Caution: This disconnects adapters!
@ -752,15 +715,74 @@ if ($NetATC){
Set-NetAdapterAdvancedProperty -CimSession $Servers -InterfaceDescription Mellanox* -DisplayName 'Dcbxmode' -DisplayValue 'Host in charge'
}
}
#endregion
#Configure SMB Bandwidth Limits for Live Migration https://techcommunity.microsoft.com/t5/Failover-Clustering/Optimizing-Hyper-V-Live-Migrations-on-an-Hyperconverged/ba-p/396609
#note: this should be normally configured with NetATC... docs needed https://techcommunity.microsoft.com/t5/networking-blog/network-atc-what-s-coming-in-azure-stack-hci-22h2/ba-p/3598442
#install feature
Invoke-Command -ComputerName $servers -ScriptBlock {Install-WindowsFeature -Name "FS-SMBBW"}
#Calculate 40% of capacity of NICs in vSwitch (considering 2 NICs, if 1 fails, it will not consume all bandwith, therefore 40%)
$Adapters=(Get-VMSwitch -CimSession $Servers[0]).NetAdapterInterfaceDescriptions
$BytesPerSecond=((Get-NetAdapter -CimSession $Servers[0] -InterfaceDescription $adapters).TransmitLinkSpeed | Measure-Object -Sum).Sum/8
Set-SmbBandwidthLimit -Category LiveMigration -BytesPerSecond ($BytesPerSecond*0.4) -CimSession $Servers
#region Check settings before applying NetATC
#Check what networks were excluded from Live Migration
$Networks=(Get-ClusterResourceType -Cluster $clustername -Name "Virtual Machine" | Get-ClusterParameter -Name MigrationExcludeNetworks).Value -split ";"
foreach ($Network in $Networks){Get-ClusterNetwork -Cluster $ClusterName | Where-Object ID -Match $Network}
#check Live Migration option
Get-VMHost -CimSession $Servers | Select-Object *Migration*
#Check smbbandwith limit cluster settings
Get-Cluster -Name $ClusterName | Select-Object *SMB*
#check SMBBandwidthLimit settings
Get-SmbBandwidthLimit -CimSession $Servers
#check VLAN settings
Get-VMNetworkAdapterIsolation -CimSession $Servers -ManagementOS
#endregion
#region Adjust NetATC global overrides
Invoke-Command -ComputerName $Servers[0] -ScriptBlock {
Import-Module NetworkATC
$overrides=New-NetIntentGlobalClusterOverrides
$overrides.MaximumVirtualMachineMigrations=4
$overrides.MaximumSMBMigrationBandwidthInGbps=20 #assuming you have 25Gbps NICs
$overrides.VirtualMachineMigrationPerformanceOption="SMB"
Set-NetIntent -GlobalClusterOverrides $overrides
}
Start-Sleep 20 #let intent propagate a bit
Write-Output "applying overrides intent"
do {
$status=Invoke-Command -ComputerName $Servers[0] -ScriptBlock {Get-NetIntentStatus -Globaloverrides}
Write-Host "." -NoNewline
Start-Sleep 5
} while ($status.ConfigurationStatus -contains "Provisioning" -or $status.ConfigurationStatus -contains "Retrying")
#endregion
#region verify settings again
#Check Cluster Global overrides
Invoke-Command -ComputerName $ClusterName -ScriptBlock {
Import-Module NetworkATC
$GlobalOverrides=Get-Netintent -GlobalOverrides
$GlobalOverrides.ClusterOverride
}
#check Live Migration option
Get-VMHost -CimSession $Servers | Select-Object *Migration*
#Check LiveMigrationPerf option and Limit (it was disabled)
Get-Cluster -Name $ClusterName | Select-Object *SMB*
#check SMBBandwidthLimit settings (is now 20Gbps = 2.5GBps = 2500000000)
Get-SmbBandwidthLimit -CimSession $Servers
#endregion
#remove net intent global overrides if necessary
<#
Invoke-Command -ComputerName $servers[0] -ScriptBlock {
Import-Module NetworkATC
Remove-NetIntent -GlobalOverrides
$overrides=New-NetIntentGlobalClusterOverrides
#add empty intent
Add-NetIntent -GlobalClusterOverrides $overrides
}
#>
}
#endregion
@ -1178,7 +1200,7 @@ if ((Get-CimInstance -ClassName win32_computersystem -CimSession $Servers[0]).Ma
$ComputersInfo = Invoke-Command -ComputerName $servers -ScriptBlock {
Get-ItemProperty -Path $using:RegistryPath
}
$ComputersInfo | Select-Object PSComputerName,CurrentBuildNumber,UBR
$ComputersInfo | Select-Object PSComputerName,ProductName,DisplayVersion,UBR
#check last driver update status
Invoke-Command -ComputerName $Servers -ScriptBlock {

Просмотреть файл

@ -1,4 +1,4 @@
## Notes:
* Notice AllowedVLANs in labconfig (to simulate VLANs configuration in NetATC)
* CreateParentDisk will create VHD with name AzSHCI**21**H2_G2.vhdx even with 22h2 media. Please rename VHDx manually
* Make sure you use latest 21H2 cumulative update (at least version 20348.1070 - september preview CU) as there are new cluster parameters (not yet used in lab), but it might be useful
* Make sure you use latest 22H2 cumulative update (at least version 20348.1070 - september preview CU) as there are new cluster parameters (not yet used in lab), but it might be useful