hwmon: Add new attributes to sysfs ABI
Add the following attributes to the sysfs ABI. in[0-*]_average in[0-*]_lowest in[0-*]_highest in[0-*]_reset_history in_reset_history curr[1-*]_average curr[1-*]_lowest curr[1-*]_highest curr[1-*]_reset_history curr_reset_history Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Reviewed-by: Robert Coulson <robert.coulson@ericsson.com>
This commit is contained in:
Родитель
c6bfb767e4
Коммит
0084e9faab
|
@ -139,6 +139,29 @@ in[0-*]_input Voltage input value.
|
|||
thumb: drivers should report the voltage values at the
|
||||
"pins" of the chip.
|
||||
|
||||
in[0-*]_average
|
||||
Average voltage
|
||||
Unit: millivolt
|
||||
RO
|
||||
|
||||
in[0-*]_lowest
|
||||
Historical minimum voltage
|
||||
Unit: millivolt
|
||||
RO
|
||||
|
||||
in[0-*]_highest
|
||||
Historical maximum voltage
|
||||
Unit: millivolt
|
||||
RO
|
||||
|
||||
in[0-*]_reset_history
|
||||
Reset inX_lowest and inX_highest
|
||||
WO
|
||||
|
||||
in_reset_history
|
||||
Reset inX_lowest and inX_highest for all sensors
|
||||
WO
|
||||
|
||||
in[0-*]_label Suggested voltage channel label.
|
||||
Text string
|
||||
Should only be created if the driver has hints about what
|
||||
|
@ -407,6 +430,29 @@ curr[1-*]_input Current input value
|
|||
Unit: milliampere
|
||||
RO
|
||||
|
||||
curr[1-*]_average
|
||||
Average current use
|
||||
Unit: milliampere
|
||||
RO
|
||||
|
||||
curr[1-*]_lowest
|
||||
Historical minimum current
|
||||
Unit: milliampere
|
||||
RO
|
||||
|
||||
curr[1-*]_highest
|
||||
Historical maximum current
|
||||
Unit: milliampere
|
||||
RO
|
||||
|
||||
curr[1-*]_reset_history
|
||||
Reset currX_lowest and currX_highest
|
||||
WO
|
||||
|
||||
curr_reset_history
|
||||
Reset currX_lowest and currX_highest for all sensors
|
||||
WO
|
||||
|
||||
Also see the Alarms section for status flags associated with currents.
|
||||
|
||||
*********
|
||||
|
|