hwmon: Document temp[1-*]_min_hyst sysfs attribute
The temp[1-*]_min_hyst sysfs attribute is already implemented by 3 hwmon drivers (adt7x10, lm77 and lm92) but was missing from the standard interface. Also add temp[1-*]_lcrit_hyst for consistency, even though no driver implement that one for the time being. Signed-off-by: Jean Delvare <jdelvare@suse.de> Reviewed-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Родитель
4b660a7f5c
Коммит
0132514588
|
@ -327,6 +327,13 @@ temp[1-*]_max_hyst
|
|||
from the max value.
|
||||
RW
|
||||
|
||||
temp[1-*]_min_hyst
|
||||
Temperature hysteresis value for min limit.
|
||||
Unit: millidegree Celsius
|
||||
Must be reported as an absolute temperature, NOT a delta
|
||||
from the min value.
|
||||
RW
|
||||
|
||||
temp[1-*]_input Temperature input value.
|
||||
Unit: millidegree Celsius
|
||||
RO
|
||||
|
@ -362,6 +369,13 @@ temp[1-*]_lcrit Temperature critical min value, typically lower than
|
|||
Unit: millidegree Celsius
|
||||
RW
|
||||
|
||||
temp[1-*]_lcrit_hyst
|
||||
Temperature hysteresis value for critical min limit.
|
||||
Unit: millidegree Celsius
|
||||
Must be reported as an absolute temperature, NOT a delta
|
||||
from the critical min value.
|
||||
RW
|
||||
|
||||
temp[1-*]_offset
|
||||
Temperature offset which is added to the temperature reading
|
||||
by the chip.
|
||||
|
|
Загрузка…
Ссылка в новой задаче