regulator: pwm-regulator: Re-write bindings
* Add support for continuous-voltage mode * Put more meat on the bones with regards to voltage-table mode * Sort out formatting for ease of consumption Cc: devicetree@vger.kernel.org Signed-off-by: Lee Jones <lee.jones@linaro.org> Signed-off-by: Mark Brown <broonie@kernel.org>
This commit is contained in:
Родитель
f9178dad67
Коммит
02258b8bcb
|
@ -1,27 +1,71 @@
|
|||
pwm regulator bindings
|
||||
Bindings for the Generic PWM Regulator
|
||||
======================================
|
||||
|
||||
Currently supports 2 modes of operation:
|
||||
|
||||
voltage-table: When in this mode, a voltage table (See below) of
|
||||
predefined voltage <=> duty-cycle values must be
|
||||
provided via DT. Limitations are that the regulator can
|
||||
only operate at the voltages supplied in the table.
|
||||
Intermediary duty-cycle values which would normally
|
||||
allow finer grained voltage selection are ignored and
|
||||
rendered useless. Although more control is given to
|
||||
the user if the assumptions made in continuous-voltage
|
||||
mode do not reign true.
|
||||
|
||||
continuous-voltage: This mode uses the regulator's maximum and minimum
|
||||
supplied voltages specified in the
|
||||
regulator-{min,max}-microvolt properties to calculate
|
||||
appropriate duty-cycle values. This allows for a much
|
||||
more fine grained solution when compared with
|
||||
voltage-table mode above. This solution does make an
|
||||
assumption that a %50 duty-cycle value will cause the
|
||||
regulator voltage to run at half way between the
|
||||
supplied max_uV and min_uV values.
|
||||
|
||||
Required properties:
|
||||
- compatible: Should be "pwm-regulator"
|
||||
- pwms: OF device-tree PWM specification (see PWM binding pwm.txt)
|
||||
- voltage-table: voltage and duty table, include 2 members in each set of
|
||||
brackets, first one is voltage(unit: uv), the next is duty(unit: percent)
|
||||
--------------------
|
||||
- compatible: Should be "pwm-regulator"
|
||||
|
||||
Any property defined as part of the core regulator binding defined in
|
||||
regulator.txt can also be used.
|
||||
- pwms: PWM specification (See: ../pwm/pwm.txt)
|
||||
|
||||
Example:
|
||||
One of these must be provided:
|
||||
- voltage-table: Voltage and Duty-Cycle table consisting of 2 cells
|
||||
First cell is voltage in microvolts (uV)
|
||||
Second cell is duty-cycle in percent (%)
|
||||
|
||||
- max-duty-cycle: Maximum Duty-Cycle value -- this will normally be
|
||||
255 (0xff) for an 8 bit PWM device
|
||||
|
||||
If both are provided, the current default is voltage-table mode.
|
||||
|
||||
Any property defined as part of the core regulator binding can also be used.
|
||||
(See: ../regulator/regulator.txt)
|
||||
|
||||
Continuous Voltage Example:
|
||||
pwm_regulator {
|
||||
compatible = "pwm-regulator;
|
||||
pwms = <&pwm1 0 8448 0>;
|
||||
regulator-min-microvolt = <1016000>;
|
||||
regulator-max-microvolt = <1114000>;
|
||||
regulator-name = "vdd_logic";
|
||||
|
||||
max-duty-cycle = <255>; /* 8bit PWM */
|
||||
};
|
||||
|
||||
Voltage Table Example:
|
||||
pwm_regulator {
|
||||
compatible = "pwm-regulator;
|
||||
pwms = <&pwm1 0 8448 0>;
|
||||
regulator-min-microvolt = <1016000>;
|
||||
regulator-max-microvolt = <1114000>;
|
||||
regulator-name = "vdd_logic";
|
||||
|
||||
/* Voltage Duty-Cycle */
|
||||
voltage-table = <1114000 0>,
|
||||
<1095000 10>,
|
||||
<1076000 20>,
|
||||
<1056000 30>,
|
||||
<1036000 40>,
|
||||
<1016000 50>;
|
||||
|
||||
regulator-min-microvolt = <1016000>;
|
||||
regulator-max-microvolt = <1114000>;
|
||||
regulator-name = "vdd_logic";
|
||||
};
|
||||
|
|
Загрузка…