power: supply: document current direction
Currently the sign for CURRENT_NOW and CURRENT_AVG is a bit of a mess. There are basically 3 different ways battery fuel gauges report the current: 1. uses negative values for discharging and positive values for charging 2. uses positive values for discharging and negative values for discharging (opposit of 1) 3. only uses positive values As a result userspace currently cannot use the sign at all in a generic way. Let's solve the issue by documenting a canonical way for reporting the data and ensure new drivers follow this way. Then existing drivers can be fixed on a case-by-case basis. The 'negative value = battery discharging' has been choosen, since there are only very few drivers doing it the other way around. Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Родитель
41a7431dba
Коммит
05f94eb989
|
@ -108,7 +108,8 @@ Description:
|
|||
which they average readings to smooth out the reported value.
|
||||
|
||||
Access: Read
|
||||
Valid values: Represented in microamps
|
||||
Valid values: Represented in microamps. Negative values are used
|
||||
for discharging batteries, positive values for charging batteries.
|
||||
|
||||
What: /sys/class/power_supply/<supply_name>/current_max
|
||||
Date: October 2010
|
||||
|
@ -127,7 +128,8 @@ Description:
|
|||
This value is not averaged/smoothed.
|
||||
|
||||
Access: Read
|
||||
Valid values: Represented in microamps
|
||||
Valid values: Represented in microamps. Negative values are used
|
||||
for discharging batteries, positive values for charging batteries.
|
||||
|
||||
What: /sys/class/power_supply/<supply_name>/charge_control_limit
|
||||