mac80211: (really) fix rates setup on IBSS merge

when an IBSS merge happened, the supported rates for the newly added station
were left empty, causing the rate control module to be initialized with only
the basic rates.

the section of the ibss code which deals with updating supported rates for
an already existing station failed to inform the rate control module about the
new rates. as both minstrel and pid don't have an update function i just use
the init function.

also remove unnecessary (unsigned long long) casts and edit debug message.

Signed-off-by: Bruno Randolf <br1@einfach.org>
Signed-off-by: John W. Linville <linville@tuxdriver.com>
This commit is contained in:
Bruno Randolf 2010-03-03 18:45:42 +09:00 коммит произвёл John W. Linville
Родитель 819386dfc6
Коммит 09a08cff3d
1 изменённых файлов: 8 добавлений и 8 удалений

Просмотреть файл

@ -264,17 +264,16 @@ static void ieee80211_rx_bss_info(struct ieee80211_sub_if_data *sdata,
sta->sta.supp_rates[band] = supp_rates |
ieee80211_mandatory_rates(local, band);
if (sta->sta.supp_rates[band] != prev_rates) {
#ifdef CONFIG_MAC80211_IBSS_DEBUG
if (sta->sta.supp_rates[band] != prev_rates)
printk(KERN_DEBUG "%s: updated supp_rates set "
"for %pM based on beacon info (0x%llx | "
"0x%llx -> 0x%llx)\n",
sdata->name,
sta->sta.addr,
(unsigned long long) prev_rates,
(unsigned long long) supp_rates,
(unsigned long long) sta->sta.supp_rates[band]);
"for %pM based on beacon/probe_response "
"(0x%x -> 0x%x)\n",
sdata->name, sta->sta.addr,
prev_rates, sta->sta.supp_rates[band]);
#endif
rate_control_rate_init(sta);
}
rcu_read_unlock();
} else {
rcu_read_unlock();
@ -370,6 +369,7 @@ static void ieee80211_rx_bss_info(struct ieee80211_sub_if_data *sdata,
sdata->name, mgmt->bssid);
#endif
ieee80211_sta_join_ibss(sdata, bss);
supp_rates = ieee80211_sta_get_rates(local, elems, band);
ieee80211_ibss_add_sta(sdata, mgmt->bssid, mgmt->sa,
supp_rates, GFP_KERNEL);
}