fanotify: FAN_MARK_FLUSH: avoid having to provide a fake/invalid fd and path
Originally from Tvrtko Ursulin (https://lkml.org/lkml/2011/1/12/112) Avoid having to provide a fake/invalid fd and path when flushing marks Currently for a group to flush marks it has set it needs to provide a fake or invalid (but resolvable) file descriptor and path when calling fanotify_mark. This patch pulls the flush handling a bit up so file descriptor and path are completely ignored when flushing. I reworked the patch to be applicable again (the signature of fanotify_mark has changed since Tvrtko's work). Signed-off-by: Heinrich Schuchardt <xypron.glpk@gmx.de> Cc: Tvrtko Ursulin <tvrtko.ursulin@onelan.co.uk> Reviewed-by: Jan Kara <jack@suse.cz> Acked-by: Eric Paris <eparis@redhat.com> Signed-off-by: Andrew Morton <akpm@linux-foundation.org> Signed-off-by: Linus Torvalds <torvalds@linux-foundation.org>
This commit is contained in:
Родитель
3185a88ce3
Коммит
0a8dd2db57
|
@ -813,6 +813,15 @@ SYSCALL_DEFINE5(fanotify_mark, int, fanotify_fd, unsigned int, flags,
|
|||
group->priority == FS_PRIO_0)
|
||||
goto fput_and_out;
|
||||
|
||||
if (flags & FAN_MARK_FLUSH) {
|
||||
ret = 0;
|
||||
if (flags & FAN_MARK_MOUNT)
|
||||
fsnotify_clear_vfsmount_marks_by_group(group);
|
||||
else
|
||||
fsnotify_clear_inode_marks_by_group(group);
|
||||
goto fput_and_out;
|
||||
}
|
||||
|
||||
ret = fanotify_find_path(dfd, pathname, &path, flags);
|
||||
if (ret)
|
||||
goto fput_and_out;
|
||||
|
@ -824,7 +833,7 @@ SYSCALL_DEFINE5(fanotify_mark, int, fanotify_fd, unsigned int, flags,
|
|||
mnt = path.mnt;
|
||||
|
||||
/* create/update an inode mark */
|
||||
switch (flags & (FAN_MARK_ADD | FAN_MARK_REMOVE | FAN_MARK_FLUSH)) {
|
||||
switch (flags & (FAN_MARK_ADD | FAN_MARK_REMOVE)) {
|
||||
case FAN_MARK_ADD:
|
||||
if (flags & FAN_MARK_MOUNT)
|
||||
ret = fanotify_add_vfsmount_mark(group, mnt, mask, flags);
|
||||
|
@ -837,12 +846,6 @@ SYSCALL_DEFINE5(fanotify_mark, int, fanotify_fd, unsigned int, flags,
|
|||
else
|
||||
ret = fanotify_remove_inode_mark(group, inode, mask, flags);
|
||||
break;
|
||||
case FAN_MARK_FLUSH:
|
||||
if (flags & FAN_MARK_MOUNT)
|
||||
fsnotify_clear_vfsmount_marks_by_group(group);
|
||||
else
|
||||
fsnotify_clear_inode_marks_by_group(group);
|
||||
break;
|
||||
default:
|
||||
ret = -EINVAL;
|
||||
}
|
||||
|
|
Загрузка…