hwmon: (lm95241) Fix negative temperature results
Negative temperatures were returned in degrees C instead of milli-Degrees C. Also, negative temperatures were reported for remote temperature sensors even if the chip was configured for positive-only results. Fix by detecting temperature modes, and by treating negative temperatures similar to positive temperatures, with appropriate sign extension. Signed-off-by: Guenter Roeck <guenter.roeck@ericsson.com> Acked-by: Jean Delvare <khali@linux-fr.org> Cc: stable@kernel.org # 2.6.30+
This commit is contained in:
Родитель
27739e694a
Коммит
0c2a40e2fe
|
@ -98,11 +98,16 @@ struct lm95241_data {
|
|||
};
|
||||
|
||||
/* Conversions */
|
||||
static int TempFromReg(u8 val_h, u8 val_l)
|
||||
static int temp_from_reg_signed(u8 val_h, u8 val_l)
|
||||
{
|
||||
if (val_h & 0x80)
|
||||
return val_h - 0x100;
|
||||
return val_h * 1000 + val_l * 1000 / 256;
|
||||
s16 val_hl = (val_h << 8) | val_l;
|
||||
return val_hl * 1000 / 256;
|
||||
}
|
||||
|
||||
static int temp_from_reg_unsigned(u8 val_h, u8 val_l)
|
||||
{
|
||||
u16 val_hl = (val_h << 8) | val_l;
|
||||
return val_hl * 1000 / 256;
|
||||
}
|
||||
|
||||
static struct lm95241_data *lm95241_update_device(struct device *dev)
|
||||
|
@ -135,10 +140,13 @@ static ssize_t show_input(struct device *dev, struct device_attribute *attr,
|
|||
char *buf)
|
||||
{
|
||||
struct lm95241_data *data = lm95241_update_device(dev);
|
||||
int index = to_sensor_dev_attr(attr)->index;
|
||||
|
||||
return snprintf(buf, PAGE_SIZE - 1, "%d\n",
|
||||
TempFromReg(data->temp[to_sensor_dev_attr(attr)->index],
|
||||
data->temp[to_sensor_dev_attr(attr)->index + 1]));
|
||||
index == 0 || (data->config & (1 << (index / 2))) ?
|
||||
temp_from_reg_signed(data->temp[index], data->temp[index + 1]) :
|
||||
temp_from_reg_unsigned(data->temp[index],
|
||||
data->temp[index + 1]));
|
||||
}
|
||||
|
||||