arm: dts: mediatek: Add missing cooling device properties for CPUs

The cooling device properties, like "#cooling-cells" and
"dynamic-power-coefficient", should either be present for all the CPUs
of a cluster or none. If these are present only for a subset of CPUs of
a cluster then things will start falling apart as soon as the CPUs are
brought online in a different order. For example, this will happen
because the operating system looks for such properties in the CPU node
it is trying to bring up, so that it can register a cooling device.

Add such missing properties.

Signed-off-by: Viresh Kumar <viresh.kumar@linaro.org>
Signed-off-by: Matthias Brugger <matthias.bgg@gmail.com>
This commit is contained in:
Viresh Kumar 2018-05-25 16:01:49 +05:30 коммит произвёл Matthias Brugger
Родитель ce397d215c
Коммит 0c7f7a5150
1 изменённых файлов: 3 добавлений и 0 удалений

Просмотреть файл

@ -92,6 +92,7 @@
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
#cooling-cells = <2>;
clock-frequency = <1300000000>;
};
@ -103,6 +104,7 @@
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
#cooling-cells = <2>;
clock-frequency = <1300000000>;
};
@ -114,6 +116,7 @@
<&apmixedsys CLK_APMIXED_MAINPLL>;
clock-names = "cpu", "intermediate";
operating-points-v2 = <&cpu_opp_table>;
#cooling-cells = <2>;
clock-frequency = <1300000000>;
};
};