regulator: palmas: Fix off-by-one for ramp_delay and register value mapping
Datasheet says: Time Step (TSTEP) selection, when changing the output voltage, the new value is reached through successive voltage steps (if not bypassed). The equivalent programmable slew rate of the output voltage is: TSTEP[1:0]: 00 Jump (no slope control) TSTEP[1:0]: 01 10mV/us TSTEP[1:0]: 10 5mV/us (default) TSTEP[1:0]: 11 2.5mV/us Signed-off-by: Axel Lin <axel.lin@ingics.com> Acked-by: Laxman Dewangan <ldewangan@nvidia.com> Signed-off-by: Mark Brown <broonie@opensource.wolfsonmicro.com>
This commit is contained in:
Родитель
e31089c608
Коммит
0ea34b5786
|
@ -447,9 +447,9 @@ static int palmas_smps_set_ramp_delay(struct regulator_dev *rdev,
|
|||
|
||||
if (ramp_delay <= 0)
|
||||
reg = 0;
|
||||
else if (ramp_delay < 2500)
|
||||
else if (ramp_delay <= 2500)
|
||||
reg = 3;
|
||||
else if (ramp_delay < 5000)
|
||||
else if (ramp_delay <= 5000)
|
||||
reg = 2;
|
||||
else
|
||||
reg = 1;
|
||||
|
|
Загрузка…
Ссылка в новой задаче