PCI: Work around Stratus ftServer broken PCIe hierarchy (fix DMI check)
Commit 284f5f9
was intended to disable the "only_one_child()" optimization
on Stratus ftServer systems, but its DMI check is wrong. It looks for
DMI_SYS_VENDOR that contains "ftServer", when it should look for
DMI_SYS_VENDOR containing "Stratus" and DMI_PRODUCT_NAME containing
"ftServer".
Tested on Stratus ftServer 6400.
Reported-by: Fadeeva Marina <astarta@rat.ru>
Reference: https://bugzilla.kernel.org/show_bug.cgi?id=51331
Signed-off-by: Myron Stowe <myron.stowe@redhat.com>
Signed-off-by: Bjorn Helgaas <bhelgaas@google.com>
CC: stable@vger.kernel.org # v3.5+
This commit is contained in:
Родитель
faa48a507f
Коммит
1278998f8f
|
@ -434,7 +434,8 @@ static const struct dmi_system_id __devinitconst pciprobe_dmi_table[] = {
|
||||||
.callback = set_scan_all,
|
.callback = set_scan_all,
|
||||||
.ident = "Stratus/NEC ftServer",
|
.ident = "Stratus/NEC ftServer",
|
||||||
.matches = {
|
.matches = {
|
||||||
DMI_MATCH(DMI_SYS_VENDOR, "ftServer"),
|
DMI_MATCH(DMI_SYS_VENDOR, "Stratus"),
|
||||||
|
DMI_MATCH(DMI_PRODUCT_NAME, "ftServer"),
|
||||||
},
|
},
|
||||||
},
|
},
|
||||||
{}
|
{}
|
||||||
|
|
Загрузка…
Ссылка в новой задаче