[POWERPC] EEH: support ibm,get-config-addr-info2 RTAS call

Provide support for the new ibm,get-config-addr-info2 RTAS token,
whenever it is actually available.

Signed-off-by: Linas Vepstas <linas@austin.ibm.com>
Signed-off-by: Paul Mackerras <paulus@samba.org>
This commit is contained in:
Linas Vepstas 2007-03-19 14:54:21 -05:00 коммит произвёл Paul Mackerras
Родитель 2fd30be8da
Коммит 147d6a3750
1 изменённых файлов: 35 добавлений и 9 удалений

Просмотреть файл

@ -83,6 +83,7 @@ static int ibm_read_slot_reset_state;
static int ibm_read_slot_reset_state2;
static int ibm_slot_error_detail;
static int ibm_get_config_addr_info;
static int ibm_get_config_addr_info2;
static int ibm_configure_bridge;
int eeh_subsystem_enabled;
@ -744,6 +745,38 @@ struct eeh_early_enable_info {
unsigned int buid_lo;
};
static int get_pe_addr (int config_addr,
struct eeh_early_enable_info *info)
{
unsigned int rets[3];
int ret;
/* Use latest config-addr token on power6 */
if (ibm_get_config_addr_info2 != RTAS_UNKNOWN_SERVICE) {
/* Make sure we have a PE in hand */
ret = rtas_call (ibm_get_config_addr_info2, 4, 2, rets,
config_addr, info->buid_hi, info->buid_lo, 1);
if (ret || (rets[0]==0))
return 0;
ret = rtas_call (ibm_get_config_addr_info2, 4, 2, rets,
config_addr, info->buid_hi, info->buid_lo, 0);
if (ret)
return 0;
return rets[0];
}
/* Use older config-addr token on power5 */
if (ibm_get_config_addr_info != RTAS_UNKNOWN_SERVICE) {
ret = rtas_call (ibm_get_config_addr_info, 4, 2, rets,
config_addr, info->buid_hi, info->buid_lo, 0);
if (ret)
return 0;
return rets[0];
}
return 0;
}
/* Enable eeh for the given device node. */
static void *early_enable_eeh(struct device_node *dn, void *data)
{
@ -810,15 +843,7 @@ static void *early_enable_eeh(struct device_node *dn, void *data)
/* If the newer, better, ibm,get-config-addr-info is supported,
* then use that instead. */
pdn->eeh_pe_config_addr = 0;
if (ibm_get_config_addr_info != RTAS_UNKNOWN_SERVICE) {
ret = rtas_call (ibm_get_config_addr_info, 4, 2, rets,
pdn->eeh_config_addr,
info->buid_hi, info->buid_lo,
0);
if (ret == 0)
pdn->eeh_pe_config_addr = rets[0];
}
pdn->eeh_pe_config_addr = get_pe_addr(pdn->eeh_config_addr, info);
/* Some older systems (Power4) allow the
* ibm,set-eeh-option call to succeed even on nodes
@ -889,6 +914,7 @@ void __init eeh_init(void)
ibm_read_slot_reset_state = rtas_token("ibm,read-slot-reset-state");
ibm_slot_error_detail = rtas_token("ibm,slot-error-detail");
ibm_get_config_addr_info = rtas_token("ibm,get-config-addr-info");
ibm_get_config_addr_info2 = rtas_token("ibm,get-config-addr-info2");
ibm_configure_bridge = rtas_token ("ibm,configure-bridge");
if (ibm_set_eeh_option == RTAS_UNKNOWN_SERVICE)