s390/fpu: signals vs. floating point control register

git commit 904818e2f2
"s390/kernel: introduce fpu-internal.h with fpu helper functions"
introduced the fpregs_store / fp_regs_load helper. These function
fail to save and restore the floating pointer control registers.

The effect is that the FPC is not correctly handled on signal
delivery and signal return.

Cc: stable@vger.kernel.org # 4.4
Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
Martin Schwidefsky 2016-02-19 15:29:05 +01:00
Родитель 342300cc9c
Коммит 1b17cb796f
1 изменённых файлов: 2 добавлений и 0 удалений

Просмотреть файл

@ -40,6 +40,7 @@ static inline void convert_fp_to_vx(__vector128 *vxrs, freg_t *fprs)
static inline void fpregs_store(_s390_fp_regs *fpregs, struct fpu *fpu)
{
fpregs->pad = 0;
fpregs->fpc = fpu->fpc;
if (MACHINE_HAS_VX)
convert_vx_to_fp((freg_t *)&fpregs->fprs, fpu->vxrs);
else
@ -49,6 +50,7 @@ static inline void fpregs_store(_s390_fp_regs *fpregs, struct fpu *fpu)
static inline void fpregs_load(_s390_fp_regs *fpregs, struct fpu *fpu)
{
fpu->fpc = fpregs->fpc;
if (MACHINE_HAS_VX)
convert_fp_to_vx(fpu->vxrs, (freg_t *)&fpregs->fprs);
else