iio: adc: at91-sama5d2_adc: get rid of 5 degrees Celsius adjustment
On SAMA7G5 final chip version there is no need for 5 degrees Celsius
adjustment when computing junction temperature, thus, remove it.
Fixes: 5ab38b8189
("iio: adc: at91-sama5d2_adc: add support for temperature sensor")
Signed-off-by: Claudiu Beznea <claudiu.beznea@microchip.com>
Link: https://lore.kernel.org/r/20221020102705.3639204-1-claudiu.beznea@microchip.com
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Родитель
efa17e90e1
Коммит
207777dc30
|
@ -2307,11 +2307,9 @@ static int at91_adc_temp_sensor_init(struct at91_adc_state *st,
|
|||
clb->p6 = buf[AT91_ADC_TS_CLB_IDX_P6];
|
||||
|
||||
/*
|
||||
* We prepare here the conversion to milli and also add constant
|
||||
* factor (5 degrees Celsius) to p1 here to avoid doing it on
|
||||
* hotpath.
|
||||
* We prepare here the conversion to milli to avoid doing it on hotpath.
|
||||
*/
|
||||
clb->p1 = clb->p1 * 1000 + 5000;
|
||||
clb->p1 = clb->p1 * 1000;
|
||||
|
||||