docs: networking: Fix failover build warnings
Currently building the net_failover docs causes a bunch of warnings to be emitted. These warnings are all related to indentation and correctly highlight missing '::' (for code sections). It looks, from other rst files in Documentation, that the first column should be indented 2 spaces. Add '::' before code snippets and indent all snippets uniformly starting with 2 spaces. Cc: Jonathan Corbet <corbet@lwn.net> Signed-off-by: Tobin C. Harding <me@tobin.cc> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Родитель
d95768d3cc
Коммит
2880984970
|
@ -36,37 +36,39 @@ feature on the virtio-net interface and assign the same MAC address to both
|
|||
virtio-net and VF interfaces.
|
||||
|
||||
Here is an example XML snippet that shows such configuration.
|
||||
::
|
||||
|
||||
<interface type='network'>
|
||||
<mac address='52:54:00:00:12:53'/>
|
||||
<source network='enp66s0f0_br'/>
|
||||
<target dev='tap01'/>
|
||||
<model type='virtio'/>
|
||||
<driver name='vhost' queues='4'/>
|
||||
<link state='down'/>
|
||||
<address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/>
|
||||
</interface>
|
||||
<interface type='hostdev' managed='yes'>
|
||||
<mac address='52:54:00:00:12:53'/>
|
||||
<source>
|
||||
<address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/>
|
||||
</source>
|
||||
<address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/>
|
||||
</interface>
|
||||
<interface type='network'>
|
||||
<mac address='52:54:00:00:12:53'/>
|
||||
<source network='enp66s0f0_br'/>
|
||||
<target dev='tap01'/>
|
||||
<model type='virtio'/>
|
||||
<driver name='vhost' queues='4'/>
|
||||
<link state='down'/>
|
||||
<address type='pci' domain='0x0000' bus='0x00' slot='0x0a' function='0x0'/>
|
||||
</interface>
|
||||
<interface type='hostdev' managed='yes'>
|
||||
<mac address='52:54:00:00:12:53'/>
|
||||
<source>
|
||||
<address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/>
|
||||
</source>
|
||||
<address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/>
|
||||
</interface>
|
||||
|
||||
Booting a VM with the above configuration will result in the following 3
|
||||
netdevs created in the VM.
|
||||
::
|
||||
|
||||
4: ens10: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
|
||||
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
||||
inet 192.168.12.53/24 brd 192.168.12.255 scope global dynamic ens10
|
||||
valid_lft 42482sec preferred_lft 42482sec
|
||||
inet6 fe80::97d8:db2:8c10:b6d6/64 scope link
|
||||
valid_lft forever preferred_lft forever
|
||||
5: ens10nsby: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc fq_codel master ens10 state UP group default qlen 1000
|
||||
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
||||
7: ens11: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master ens10 state UP group default qlen 1000
|
||||
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
||||
4: ens10: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc noqueue state UP group default qlen 1000
|
||||
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
||||
inet 192.168.12.53/24 brd 192.168.12.255 scope global dynamic ens10
|
||||
valid_lft 42482sec preferred_lft 42482sec
|
||||
inet6 fe80::97d8:db2:8c10:b6d6/64 scope link
|
||||
valid_lft forever preferred_lft forever
|
||||
5: ens10nsby: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc fq_codel master ens10 state UP group default qlen 1000
|
||||
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
||||
7: ens11: <BROADCAST,MULTICAST,UP,LOWER_UP> mtu 1500 qdisc mq master ens10 state UP group default qlen 1000
|
||||
link/ether 52:54:00:00:12:53 brd ff:ff:ff:ff:ff:ff
|
||||
|
||||
ens10 is the 'failover' master netdev, ens10nsby and ens11 are the slave
|
||||
'standby' and 'primary' netdevs respectively.
|
||||
|
@ -80,37 +82,38 @@ the paravirtual datapath when the VF is unplugged.
|
|||
|
||||
Here is a sample script that shows the steps to initiate live migration on
|
||||
the source hypervisor.
|
||||
::
|
||||
|
||||
# cat vf_xml
|
||||
<interface type='hostdev' managed='yes'>
|
||||
<mac address='52:54:00:00:12:53'/>
|
||||
<source>
|
||||
<address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/>
|
||||
</source>
|
||||
<address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/>
|
||||
</interface>
|
||||
# cat vf_xml
|
||||
<interface type='hostdev' managed='yes'>
|
||||
<mac address='52:54:00:00:12:53'/>
|
||||
<source>
|
||||
<address type='pci' domain='0x0000' bus='0x42' slot='0x02' function='0x5'/>
|
||||
</source>
|
||||
<address type='pci' domain='0x0000' bus='0x00' slot='0x0b' function='0x0'/>
|
||||
</interface>
|
||||
|
||||
# Source Hypervisor
|
||||
#!/bin/bash
|
||||
# Source Hypervisor
|
||||
#!/bin/bash
|
||||
|
||||
DOMAIN=fedora27-tap01
|
||||
PF=enp66s0f0
|
||||
VF_NUM=5
|
||||
TAP_IF=tap01
|
||||
VF_XML=
|
||||
DOMAIN=fedora27-tap01
|
||||
PF=enp66s0f0
|
||||
VF_NUM=5
|
||||
TAP_IF=tap01
|
||||
VF_XML=
|
||||
|
||||
MAC=52:54:00:00:12:53
|
||||
ZERO_MAC=00:00:00:00:00:00
|
||||
MAC=52:54:00:00:12:53
|
||||
ZERO_MAC=00:00:00:00:00:00
|
||||
|
||||
virsh domif-setlink $DOMAIN $TAP_IF up
|
||||
bridge fdb del $MAC dev $PF master
|
||||
virsh detach-device $DOMAIN $VF_XML
|
||||
ip link set $PF vf $VF_NUM mac $ZERO_MAC
|
||||
virsh domif-setlink $DOMAIN $TAP_IF up
|
||||
bridge fdb del $MAC dev $PF master
|
||||
virsh detach-device $DOMAIN $VF_XML
|
||||
ip link set $PF vf $VF_NUM mac $ZERO_MAC
|
||||
|
||||
virsh migrate --live $DOMAIN qemu+ssh://$REMOTE_HOST/system
|
||||
virsh migrate --live $DOMAIN qemu+ssh://$REMOTE_HOST/system
|
||||
|
||||
# Destination Hypervisor
|
||||
#!/bin/bash
|
||||
# Destination Hypervisor
|
||||
#!/bin/bash
|
||||
|
||||
virsh attach-device $DOMAIN $VF_XML
|
||||
virsh domif-setlink $DOMAIN $TAP_IF down
|
||||
virsh attach-device $DOMAIN $VF_XML
|
||||
virsh domif-setlink $DOMAIN $TAP_IF down
|
||||
|
|
Загрузка…
Ссылка в новой задаче