net: hns: Fix loopback test failed at copper ports
When doing a loopback test at copper ports, the serdes loopback and the phy loopback will fail, because of the adjust link had not finished, and phy not ready. Adds sleep between adjust link and test process to fix it. Signed-off-by: Yonglong Liu <liuyonglong@huawei.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Родитель
62394708f3
Коммит
2e1f164861
|
@ -339,6 +339,7 @@ static int __lb_setup(struct net_device *ndev,
|
|||
static int __lb_up(struct net_device *ndev,
|
||||
enum hnae_loop loop_mode)
|
||||
{
|
||||
#define NIC_LB_TEST_WAIT_PHY_LINK_TIME 300
|
||||
struct hns_nic_priv *priv = netdev_priv(ndev);
|
||||
struct hnae_handle *h = priv->ae_handle;
|
||||
int speed, duplex;
|
||||
|
@ -365,6 +366,9 @@ static int __lb_up(struct net_device *ndev,
|
|||
|
||||
h->dev->ops->adjust_link(h, speed, duplex);
|
||||
|
||||
/* wait adjust link done and phy ready */
|
||||
msleep(NIC_LB_TEST_WAIT_PHY_LINK_TIME);
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
|
|
Загрузка…
Ссылка в новой задаче