i2c: i2c-bfin-twi: Tighten condition when failing I2C transfer if MEN bit is reset unexpectedly.

In order to mark I2C transfer fail when MEN bit in I2C controller is
reset unexpectedly in MCOMP interrupt, interrupt status bits XMTSERV or
RCVSERV should be checked.

Master Transfer Complete (MCOMP).
[1] The initiated master transfer has completed. In the absence of a
repeat start, the bus has been released.
[0] The completion of a transfer has not been detected.

Signed-off-by: Sonic Zhang <sonic.zhang@analog.com>

[wsa: fixed spaces around operators and typo in commit message]

Signed-off-by: Wolfram Sang <w.sang@pengutronix.de>
This commit is contained in:
Sonic Zhang 2012-06-13 16:22:43 +08:00 коммит произвёл Wolfram Sang
Родитель a25733d6f6
Коммит 2ee74eb95c
1 изменённых файлов: 2 добавлений и 1 удалений

Просмотреть файл

@ -201,7 +201,8 @@ static void bfin_twi_handle_interrupt(struct bfin_twi_iface *iface,
return;
}
if (twi_int_status & MCOMP) {
if ((read_MASTER_CTL(iface) & MEN) == 0 &&
if (twi_int_status & (XMTSERV | RCVSERV) &&
(read_MASTER_CTL(iface) & MEN) == 0 &&
(iface->cur_mode == TWI_I2C_MODE_REPEAT ||
iface->cur_mode == TWI_I2C_MODE_COMBINED)) {
iface->result = -1;