3c59x: shorten timer period for slave devices
Jean Delvare reported bonding on top of 3c59x adapters was not detecting network cable removal fast enough. 3c59x indeed uses a 60 seconds timer to check link status if carrier is on, and 5 seconds if carrier is off. This patch reduces timer period to 5 seconds if device is a bonding slave. Reported-by: Jean Delvare <jdelvare@suse.de> Acked-by: Jean Delvare <jdelvare@suse.de> Acked-by: Steffen Klassert <steffen.klassert@secunet.com> Signed-off-by: Eric Dumazet <eric.dumazet@gmail.com> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Родитель
58e05f357a
Коммит
3013dc0cce
|
@ -1842,7 +1842,7 @@ vortex_timer(unsigned long data)
|
||||||
ok = 1;
|
ok = 1;
|
||||||
}
|
}
|
||||||
|
|
||||||
if (!netif_carrier_ok(dev))
|
if (dev->flags & IFF_SLAVE || !netif_carrier_ok(dev))
|
||||||
next_tick = 5*HZ;
|
next_tick = 5*HZ;
|
||||||
|
|
||||||
if (vp->medialock)
|
if (vp->medialock)
|
||||||
|
|
Загрузка…
Ссылка в новой задаче