drm/amd/display: Right shift AUX reply value sooner than later
[Why] There is no point in keeping the AUX reply value in the raw format as returned from reading the AUX_SW_DATA register. [How] Shift it within read_channel_reply(), where the register is read, before returning it. Signed-off-by: Leo (Sunpeng) Li <sunpeng.li@amd.com> Reviewed-by: Harry Wentland <Harry.Wentland@amd.com> Signed-off-by: Alex Deucher <alexander.deucher@amd.com>
This commit is contained in:
Родитель
c2437b1f16
Коммит
3092108904
|
@ -300,9 +300,10 @@ static int read_channel_reply(struct aux_engine *engine, uint32_t size,
|
||||||
AUX_SW_DATA_RW, 1);
|
AUX_SW_DATA_RW, 1);
|
||||||
|
|
||||||
REG_GET(AUX_SW_DATA, AUX_SW_DATA, &reply_result_32);
|
REG_GET(AUX_SW_DATA, AUX_SW_DATA, &reply_result_32);
|
||||||
|
reply_result_32 = reply_result_32 >> 4;
|
||||||
*reply_result = (uint8_t)reply_result_32;
|
*reply_result = (uint8_t)reply_result_32;
|
||||||
|
|
||||||
if (reply_result_32 >> 4 == 0) { /* ACK */
|
if (reply_result_32 == 0) { /* ACK */
|
||||||
uint32_t i = 0;
|
uint32_t i = 0;
|
||||||
|
|
||||||
/* First byte was already used to get the command status */
|
/* First byte was already used to get the command status */
|
||||||
|
@ -356,7 +357,6 @@ static void process_channel_reply(
|
||||||
return;
|
return;
|
||||||
}
|
}
|
||||||
} else {
|
} else {
|
||||||
reply_result = reply_result >> 4;
|
|
||||||
|
|
||||||
switch (reply_result) {
|
switch (reply_result) {
|
||||||
case 0: /* ACK */
|
case 0: /* ACK */
|
||||||
|
|