iio: cros_ec: Set Gyroscope default frequency to 25Hz

BMI160 Minimium gyroscope frequency in normal mode is 25Hz.
When older EC firmware do not report their sensors frequencies,
use 25Hz as the minimum for gyroscope to be sure it works on BMI160.

Fixes: ae7b02ad2f ("iio: common: cros_ec_sensors: Expose cros_ec_sensors frequency range via iio sysfs")
Signed-off-by: Gwendal Grignou <gwendal@chromium.org>
Reviewed-by: Enric Balletbo i Serra <enric.balletbo@collabora.com>
Cc: <Stable@vger.kernel.org>
Signed-off-by: Jonathan Cameron <Jonathan.Cameron@huawei.com>
This commit is contained in:
Gwendal Grignou 2020-07-28 13:48:25 -07:00 коммит произвёл Jonathan Cameron
Родитель 1dffeb8b8b
Коммит 336306790b
1 изменённых файлов: 4 добавлений и 1 удалений

Просмотреть файл

@ -72,10 +72,13 @@ static void get_default_min_max_freq(enum motionsensor_type type,
switch (type) {
case MOTIONSENSE_TYPE_ACCEL:
case MOTIONSENSE_TYPE_GYRO:
*min_freq = 12500;
*max_freq = 100000;
break;
case MOTIONSENSE_TYPE_GYRO:
*min_freq = 25000;
*max_freq = 100000;
break;
case MOTIONSENSE_TYPE_MAG:
*min_freq = 5000;
*max_freq = 25000;