ixgbe: remove wait loop on autoneg for copper devices

This patch removes couple of wait loops on autoneg that are not needed.

During validation we noticed that the loops always time out, so there
should be no user impact.

Signed-off-by: Emil Tantilov <emil.s.tantilov@intel.com>
Tested-by: Phil Schmitt <phillip.j.schmitt@intel.com>
Signed-off-by: Jeff Kirsher <jeffrey.t.kirsher@intel.com>
This commit is contained in:
Emil Tantilov 2014-09-06 07:50:27 +00:00 коммит произвёл Jeff Kirsher
Родитель fe1f2a972c
Коммит 340c5203bc
1 изменённых файлов: 0 добавлений и 41 удалений

Просмотреть файл

@ -445,8 +445,6 @@ s32 ixgbe_write_phy_reg_generic(struct ixgbe_hw *hw, u32 reg_addr,
s32 ixgbe_setup_phy_link_generic(struct ixgbe_hw *hw)
{
s32 status = 0;
u32 time_out;
u32 max_time_out = 10;
u16 autoneg_reg = IXGBE_MII_AUTONEG_REG;
bool autoneg = false;
ixgbe_link_speed speed;
@ -514,25 +512,6 @@ s32 ixgbe_setup_phy_link_generic(struct ixgbe_hw *hw)
hw->phy.ops.write_reg(hw, MDIO_CTRL1,
MDIO_MMD_AN, autoneg_reg);
/* Wait for autonegotiation to finish */
for (time_out = 0; time_out < max_time_out; time_out++) {
udelay(10);
/* Restart PHY autonegotiation and wait for completion */
status = hw->phy.ops.read_reg(hw, MDIO_STAT1,
MDIO_MMD_AN,
&autoneg_reg);
autoneg_reg &= MDIO_AN_STAT1_COMPLETE;
if (autoneg_reg == MDIO_AN_STAT1_COMPLETE) {
break;
}
}
if (time_out == max_time_out) {
hw_dbg(hw, "ixgbe_setup_phy_link_generic: time out\n");
return IXGBE_ERR_LINK_SETUP;
}
return status;
}
@ -657,8 +636,6 @@ s32 ixgbe_check_phy_link_tnx(struct ixgbe_hw *hw, ixgbe_link_speed *speed,
s32 ixgbe_setup_phy_link_tnx(struct ixgbe_hw *hw)
{
s32 status;
u32 time_out;
u32 max_time_out = 10;
u16 autoneg_reg = IXGBE_MII_AUTONEG_REG;
bool autoneg = false;
ixgbe_link_speed speed;
@ -724,24 +701,6 @@ s32 ixgbe_setup_phy_link_tnx(struct ixgbe_hw *hw)
hw->phy.ops.write_reg(hw, MDIO_CTRL1,
MDIO_MMD_AN, autoneg_reg);
/* Wait for autonegotiation to finish */
for (time_out = 0; time_out < max_time_out; time_out++) {
udelay(10);
/* Restart PHY autonegotiation and wait for completion */
status = hw->phy.ops.read_reg(hw, MDIO_STAT1,
MDIO_MMD_AN,
&autoneg_reg);
autoneg_reg &= MDIO_AN_STAT1_COMPLETE;
if (autoneg_reg == MDIO_AN_STAT1_COMPLETE)
break;
}
if (time_out == max_time_out) {
hw_dbg(hw, "ixgbe_setup_phy_link_tnx: time out\n");
return IXGBE_ERR_LINK_SETUP;
}
return status;
}