net: phy: mxl-gpy: rename MMD_VEND1 macros to match datasheet

Rename the temperature sensors macros to match the names in the
datasheet.

Signed-off-by: Michael Walle <michael@walle.cc>
Reviewed-by: Andrew Lunn <andrew@lunn.ch>
Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Michael Walle 2022-12-02 15:49:00 +01:00 коммит произвёл David S. Miller
Родитель de62486449
Коммит 343a5d358e
1 изменённых файлов: 4 добавлений и 4 удалений

Просмотреть файл

@ -78,8 +78,8 @@
VSPEC1_SGMII_CTRL_ANRS)
/* Temperature sensor */
#define VPSPEC1_TEMP_STA 0x0E
#define VPSPEC1_TEMP_STA_DATA GENMASK(9, 0)
#define VSPEC1_TEMP_STA 0x0E
#define VSPEC1_TEMP_STA_DATA GENMASK(9, 0)
/* WoL */
#define VPSPEC2_WOL_CTL 0x0E06
@ -140,14 +140,14 @@ static int gpy_hwmon_read(struct device *dev,
struct phy_device *phydev = dev_get_drvdata(dev);
int ret;
ret = phy_read_mmd(phydev, MDIO_MMD_VEND1, VPSPEC1_TEMP_STA);
ret = phy_read_mmd(phydev, MDIO_MMD_VEND1, VSPEC1_TEMP_STA);
if (ret < 0)
return ret;
if (!ret)
return -ENODATA;
*value = polynomial_calc(&poly_N_to_temp,
FIELD_GET(VPSPEC1_TEMP_STA_DATA, ret));
FIELD_GET(VSPEC1_TEMP_STA_DATA, ret));
return 0;
}