iio: magnetometer: mmc35240: fix SET/RESET sequence
The RESET operation invoked in the last instance will align in the natural way all 3 axis and the chip top view. Without this, north and south are swapped. Signed-off-by: Viorel Suman <viorel.suman@intel.com> Signed-off-by: Daniel Baluta <daniel.baluta@intel.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org>
This commit is contained in:
Родитель
3ceaa2c207
Коммит
354c879dbd
|
@ -222,14 +222,15 @@ static int mmc35240_init(struct mmc35240_data *data)
|
|||
|
||||
/*
|
||||
* make sure we restore sensor characteristics, by doing
|
||||
* a RESET/SET sequence
|
||||
* a SET/RESET sequence, the axis polarity being naturally
|
||||
* aligned after RESET
|
||||
*/
|
||||
ret = mmc35240_hw_set(data, false);
|
||||
ret = mmc35240_hw_set(data, true);
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
usleep_range(MMC53240_WAIT_SET_RESET, MMC53240_WAIT_SET_RESET + 1);
|
||||
|
||||
ret = mmc35240_hw_set(data, true);
|
||||
ret = mmc35240_hw_set(data, false);
|
||||
if (ret < 0)
|
||||
return ret;
|
||||
|
||||
|
|