[SCSI] hpsa: do not consider RAID level to be part of device identity
Otherwise, after doing a RAID level migration, the disk will be disruptively removed and re-added as a different disk on rescan. Signed-off-by: Stephen M. Cameron <scameron@beardog.cce.hp.com> Signed-off-by: James Bottomley <James.Bottomley@suse.de>
This commit is contained in:
Родитель
a0b89872b3
Коммит
35dd3039e0
|
@ -657,8 +657,6 @@ static inline int device_is_the_same(struct hpsa_scsi_dev_t *dev1,
|
|||
return 0;
|
||||
if (dev1->devtype != dev2->devtype)
|
||||
return 0;
|
||||
if (dev1->raid_level != dev2->raid_level)
|
||||
return 0;
|
||||
if (dev1->bus != dev2->bus)
|
||||
return 0;
|
||||
return 1;
|
||||
|
|
Загрузка…
Ссылка в новой задаче