regulator: core: Use map_voltage_linear_range by default for list_voltage_linear_range
Use map_voltage_linear_range() if list_voltage_linear_range() is in use and nothing is set. Signed-off-by: Axel Lin <axel.lin@ingics.com> Signed-off-by: Mark Brown <broonie@linaro.org>
This commit is contained in:
Родитель
9f8c0fe954
Коммит
366986274c
|
@ -2322,6 +2322,10 @@ static int _regulator_do_set_voltage(struct regulator_dev *rdev,
|
|||
regulator_list_voltage_linear)
|
||||
ret = regulator_map_voltage_linear(rdev,
|
||||
min_uV, max_uV);
|
||||
else if (rdev->desc->ops->list_voltage ==
|
||||
regulator_list_voltage_linear_range)
|
||||
ret = regulator_map_voltage_linear_range(rdev,
|
||||
min_uV, max_uV);
|
||||
else
|
||||
ret = regulator_map_voltage_iterate(rdev,
|
||||
min_uV, max_uV);
|
||||
|
|