drm/i915: force full detect on sink count change
This patch checks for changes in sink count between short pulse hpds and forces full detect when there is a change. This will allow both detection of hotplug and unplug of panels through dongles that give only short pulse for such events. v2: changed variable type from u8 to bool (Jani) return immediately if perform_full_detect is set(Siva) v3: changed method of determining full detection from using pointer to return code (Siva) v4: changed comments to indicate meaning of return value of intel_dp_short_pulse and explain the use of return value from intel_dp_get_dpcd in intel_dp_short_pulse (Ander) Tested-by: Nathan D Ciobanu <nathan.d.ciobanu@intel.com> Signed-off-by: Sivakumar Thulasimani <sivakumar.thulasimani@intel.com> Signed-off-by: Shubhangi Shrivastava <shubhangi.shrivastava@intel.com> Reviewed-by: Ander Conselvan de Oliveira <conselvan2@gmail.com> Signed-off-by: Ander Conselvan de Oliveira <ander.conselvan.de.oliveira@intel.com> Link: http://patchwork.freedesktop.org/patch/msgid/1459341326-13142-5-git-send-email-shubhangi.shrivastava@intel.com
This commit is contained in:
Родитель
30d9aa4265
Коммит
39ff747b2f
|
@ -4273,12 +4273,19 @@ intel_dp_check_link_status(struct intel_dp *intel_dp)
|
|||
* 2. Configure link according to Receiver Capabilities
|
||||
* 3. Use Link Training from 2.5.3.3 and 3.5.1.3
|
||||
* 4. Check link status on receipt of hot-plug interrupt
|
||||
*
|
||||
* intel_dp_short_pulse - handles short pulse interrupts
|
||||
* when full detection is not required.
|
||||
* Returns %true if short pulse is handled and full detection
|
||||
* is NOT required and %false otherwise.
|
||||
*/
|
||||
static void
|
||||
static bool
|
||||
intel_dp_short_pulse(struct intel_dp *intel_dp)
|
||||
{
|
||||
struct drm_device *dev = intel_dp_to_dev(intel_dp);
|
||||
u8 sink_irq_vector;
|
||||
u8 old_sink_count = intel_dp->sink_count;
|
||||
bool ret;
|
||||
|
||||
/*
|
||||
* Clearing compliance test variables to allow capturing
|
||||
|
@ -4288,9 +4295,17 @@ intel_dp_short_pulse(struct intel_dp *intel_dp)
|
|||
intel_dp->compliance_test_type = 0;
|
||||
intel_dp->compliance_test_data = 0;
|
||||
|
||||
/* Now read the DPCD to see if it's actually running */
|
||||
if (!intel_dp_get_dpcd(intel_dp)) {
|
||||
return;
|
||||
/*
|
||||
* Now read the DPCD to see if it's actually running
|
||||
* If the current value of sink count doesn't match with
|
||||
* the value that was stored earlier or dpcd read failed
|
||||
* we need to do full detection
|
||||
*/
|
||||
ret = intel_dp_get_dpcd(intel_dp);
|
||||
|
||||
if ((old_sink_count != intel_dp->sink_count) || !ret) {
|
||||
/* No need to proceed if we are going to do full detect */
|
||||
return false;
|
||||
}
|
||||
|
||||
/* Try to read the source of the interrupt */
|
||||
|
@ -4310,6 +4325,8 @@ intel_dp_short_pulse(struct intel_dp *intel_dp)
|
|||
drm_modeset_lock(&dev->mode_config.connection_mutex, NULL);
|
||||
intel_dp_check_link_status(intel_dp);
|
||||
drm_modeset_unlock(&dev->mode_config.connection_mutex);
|
||||
|
||||
return true;
|
||||
}
|
||||
|
||||
/* XXX this is probably wrong for multiple downstream ports */
|
||||
|
@ -5043,8 +5060,12 @@ intel_dp_hpd_pulse(struct intel_digital_port *intel_dig_port, bool long_hpd)
|
|||
}
|
||||
}
|
||||
|
||||
if (!intel_dp->is_mst)
|
||||
intel_dp_short_pulse(intel_dp);
|
||||
if (!intel_dp->is_mst) {
|
||||
if (!intel_dp_short_pulse(intel_dp)) {
|
||||
intel_dp_long_pulse(intel_dp->attached_connector);
|
||||
goto put_power;
|
||||
}
|
||||
}
|
||||
}
|
||||
|
||||
ret = IRQ_HANDLED;
|
||||
|
|
Загрузка…
Ссылка в новой задаче