scsi: lpfc: Disable NPIV support if NVME is enabled
The initial implementation of NVME didn't merge with NPIV support. As such, there are several issues if NPIV is used with NVME. For now, ensure that if NVME is enabled then NPIV is not enabled. Support for NPIV with NVME will be added in the near future. Signed-off-by: Dick Kennedy <dick.kennedy@broadcom.com> Signed-off-by: James Smart <james.smart@broadcom.com> Reviewed-by: Johannes Thumshirn <jthumshirn@suse.de> Signed-off-by: Martin K. Petersen <martin.petersen@oracle.com>
This commit is contained in:
Родитель
e7981a2c72
Коммит
42270dce9d
|
@ -313,6 +313,15 @@ lpfc_vport_create(struct fc_vport *fc_vport, bool disable)
|
|||
goto error_out;
|
||||
}
|
||||
|
||||
/* NPIV is not supported if HBA has NVME enabled */
|
||||
if (phba->cfg_enable_fc4_type & LPFC_ENABLE_NVME) {
|
||||
lpfc_printf_log(phba, KERN_ERR, LOG_VPORT,
|
||||
"3189 Create VPORT failed: "
|
||||
"NPIV is not supported on NVME\n");
|
||||
rc = VPORT_INVAL;
|
||||
goto error_out;
|
||||
}
|
||||
|
||||
vpi = lpfc_alloc_vpi(phba);
|
||||
if (vpi == 0) {
|
||||
lpfc_printf_log(phba, KERN_ERR, LOG_VPORT,
|
||||
|
|
Загрузка…