dt-bindings: power: Convert battery.txt to battery.yaml
Convert the battery.txt file to yaml and fix up the examples. Signed-off-by: Dan Murphy <dmurphy@ti.com> Reviewed-by: Rob Herring <robh@kernel.org> [Fixed the regex for ocv-capacity-table and the DT example for it] Signed-off-by: Sebastian Reichel <sebastian.reichel@collabora.com>
This commit is contained in:
Родитель
466bf93153
Коммит
471dec8023
|
@ -1,87 +1,3 @@
|
|||
Battery Characteristics
|
||||
|
||||
The devicetree battery node provides static battery characteristics.
|
||||
In smart batteries, these are typically stored in non-volatile memory
|
||||
on a fuel gauge chip. The battery node should be used where there is
|
||||
no appropriate non-volatile memory, or it is unprogrammed/incorrect.
|
||||
|
||||
Upstream dts files should not include battery nodes, unless the battery
|
||||
represented cannot easily be replaced in the system by one of a
|
||||
different type. This prevents unpredictable, potentially harmful,
|
||||
behavior should a replacement that changes the battery type occur
|
||||
without a corresponding update to the dtb.
|
||||
The contents of this file has been moved to battery.yaml
|
||||
|
||||
Please note that not all charger drivers respect all of the properties.
|
||||
|
||||
Required Properties:
|
||||
- compatible: Must be "simple-battery"
|
||||
|
||||
Optional Properties:
|
||||
- over-voltage-threshold-microvolt: battery over-voltage limit
|
||||
- re-charge-voltage-microvolt: limit to automatically start charging again
|
||||
- voltage-min-design-microvolt: drained battery voltage
|
||||
- voltage-max-design-microvolt: fully charged battery voltage
|
||||
- energy-full-design-microwatt-hours: battery design energy
|
||||
- charge-full-design-microamp-hours: battery design capacity
|
||||
- trickle-charge-current-microamp: current for trickle-charge phase
|
||||
- precharge-current-microamp: current for pre-charge phase
|
||||
- precharge-upper-limit-microvolt: limit when to change to constant charging
|
||||
- charge-term-current-microamp: current for charge termination phase
|
||||
- constant-charge-current-max-microamp: maximum constant input current
|
||||
- constant-charge-voltage-max-microvolt: maximum constant input voltage
|
||||
- factory-internal-resistance-micro-ohms: battery factory internal resistance
|
||||
- ocv-capacity-table-0: An array providing the open circuit voltage (OCV)
|
||||
of the battery and corresponding battery capacity percent, which is used
|
||||
to look up battery capacity according to current OCV value. And the open
|
||||
circuit voltage unit is microvolt.
|
||||
- ocv-capacity-table-1: Same as ocv-capacity-table-0
|
||||
......
|
||||
- ocv-capacity-table-n: Same as ocv-capacity-table-0
|
||||
- ocv-capacity-celsius: An array containing the temperature in degree Celsius,
|
||||
for each of the battery capacity lookup table. The first temperature value
|
||||
specifies the OCV table 0, and the second temperature value specifies the
|
||||
OCV table 1, and so on.
|
||||
- resistance-temp-table: An array providing the temperature in degree Celsius
|
||||
and corresponding battery internal resistance percent, which is used to look
|
||||
up the resistance percent according to current temperature to get a accurate
|
||||
batterty internal resistance in different temperatures.
|
||||
|
||||
Battery properties are named, where possible, for the corresponding
|
||||
elements in enum power_supply_property, defined in
|
||||
https://git.kernel.org/pub/scm/linux/kernel/git/torvalds/linux.git/tree/include/linux/power_supply.h
|
||||
|
||||
Batteries must be referenced by chargers and/or fuel-gauges
|
||||
using a phandle. The phandle's property should be named
|
||||
"monitored-battery".
|
||||
|
||||
Example:
|
||||
|
||||
bat: battery {
|
||||
compatible = "simple-battery";
|
||||
voltage-min-design-microvolt = <3200000>;
|
||||
voltage-max-design-microvolt = <4200000>;
|
||||
energy-full-design-microwatt-hours = <5290000>;
|
||||
charge-full-design-microamp-hours = <1430000>;
|
||||
precharge-current-microamp = <256000>;
|
||||
charge-term-current-microamp = <128000>;
|
||||
constant-charge-current-max-microamp = <900000>;
|
||||
constant-charge-voltage-max-microvolt = <4200000>;
|
||||
factory-internal-resistance-micro-ohms = <250000>;
|
||||
ocv-capacity-celsius = <(-10) 0 10>;
|
||||
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>, ...;
|
||||
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>, ...;
|
||||
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>, ...;
|
||||
resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
|
||||
};
|
||||
|
||||
charger: charger@11 {
|
||||
....
|
||||
monitored-battery = <&bat>;
|
||||
...
|
||||
};
|
||||
|
||||
fuel_gauge: fuel-gauge@22 {
|
||||
....
|
||||
monitored-battery = <&bat>;
|
||||
...
|
||||
};
|
||||
|
|
|
@ -0,0 +1,144 @@
|
|||
# SPDX-License-Identifier: (GPL-2.0-only OR BSD-2-Clause)
|
||||
%YAML 1.2
|
||||
---
|
||||
$id: http://devicetree.org/schemas/power/supply/battery.yaml#
|
||||
$schema: http://devicetree.org/meta-schemas/core.yaml#
|
||||
|
||||
title: Battery Characteristics
|
||||
|
||||
maintainers:
|
||||
- Sebastian Reichel <sre@kernel.org>
|
||||
|
||||
description: |
|
||||
The devicetree battery node provides static battery characteristics.
|
||||
In smart batteries, these are typically stored in non-volatile memory
|
||||
on a fuel gauge chip. The battery node should be used where there is
|
||||
no appropriate non-volatile memory, or it is unprogrammed/incorrect.
|
||||
|
||||
Upstream dts files should not include battery nodes, unless the battery
|
||||
represented cannot easily be replaced in the system by one of a
|
||||
different type. This prevents unpredictable, potentially harmful,
|
||||
behavior should a replacement that changes the battery type occur
|
||||
without a corresponding update to the dtb.
|
||||
|
||||
Battery properties are named, where possible, for the corresponding elements
|
||||
in enum power_supply_property, defined in include/linux/power_supply.h
|
||||
|
||||
Batteries must be referenced by chargers and/or fuel-gauges using a phandle.
|
||||
The phandle's property should be named "monitored-battery".
|
||||
|
||||
properties:
|
||||
compatible:
|
||||
const: simple-battery
|
||||
|
||||
over-voltage-threshold-microvolt:
|
||||
description: battery over-voltage limit
|
||||
|
||||
re-charge-voltage-microvolt:
|
||||
description: limit to automatically start charging again
|
||||
|
||||
voltage-min-design-microvolt:
|
||||
description: drained battery voltage
|
||||
|
||||
voltage-max-design-microvolt:
|
||||
description: fully charged battery voltage
|
||||
|
||||
energy-full-design-microwatt-hours:
|
||||
description: battery design energy
|
||||
|
||||
charge-full-design-microamp-hours:
|
||||
description: battery design capacity
|
||||
|
||||
trickle-charge-current-microamp:
|
||||
description: current for trickle-charge phase
|
||||
|
||||
precharge-current-microamp:
|
||||
description: current for pre-charge phase
|
||||
|
||||
precharge-upper-limit-microvolt:
|
||||
description: limit when to change to constant charging
|
||||
|
||||
charge-term-current-microamp:
|
||||
description: current for charge termination phase
|
||||
|
||||
constant-charge-current-max-microamp:
|
||||
description: maximum constant input current
|
||||
|
||||
constant-charge-voltage-max-microvolt:
|
||||
description: maximum constant input voltage
|
||||
|
||||
factory-internal-resistance-micro-ohms:
|
||||
description: battery factory internal resistance
|
||||
|
||||
resistance-temp-table:
|
||||
description: |
|
||||
An array providing the temperature in degree Celsius
|
||||
and corresponding battery internal resistance percent, which is used to
|
||||
look up the resistance percent according to current temperature to get an
|
||||
accurate batterty internal resistance in different temperatures.
|
||||
|
||||
ocv-capacity-celsius:
|
||||
description: |
|
||||
An array containing the temperature in degree Celsius,
|
||||
for each of the battery capacity lookup table.
|
||||
|
||||
required:
|
||||
- compatible
|
||||
|
||||
patternProperties:
|
||||
'^ocv-capacity-table-[0-9]+$':
|
||||
$ref: /schemas/types.yaml#/definitions/uint32-matrix
|
||||
description: |
|
||||
An array providing the open circuit voltage (OCV)
|
||||
of the battery and corresponding battery capacity percent, which is used
|
||||
to look up battery capacity according to current OCV value. And the open
|
||||
circuit voltage unit is microvolt.
|
||||
maxItems: 100
|
||||
items:
|
||||
items:
|
||||
- description: open circuit voltage (OCV) in microvolts
|
||||
- description: battery capacity percent
|
||||
maximum: 100
|
||||
|
||||
additionalProperties: false
|
||||
|
||||
examples:
|
||||
- |
|
||||
power {
|
||||
#address-cells = <1>;
|
||||
#size-cells = <0>;
|
||||
|
||||
battery: battery {
|
||||
compatible = "simple-battery";
|
||||
over-voltage-threshold-microvolt = <4500000>;
|
||||
re-charge-voltage-microvolt = <250000>;
|
||||
voltage-min-design-microvolt = <3200000>;
|
||||
voltage-max-design-microvolt = <4200000>;
|
||||
energy-full-design-microwatt-hours = <5290000>;
|
||||
charge-full-design-microamp-hours = <1430000>;
|
||||
precharge-current-microamp = <256000>;
|
||||
precharge-upper-limit-microvolt = <2500000>;
|
||||
charge-term-current-microamp = <128000>;
|
||||
constant-charge-current-max-microamp = <900000>;
|
||||
constant-charge-voltage-max-microvolt = <4200000>;
|
||||
factory-internal-resistance-micro-ohms = <250000>;
|
||||
ocv-capacity-celsius = <(-10) 0 10>;
|
||||
/* table for -10 degree Celsius */
|
||||
ocv-capacity-table-0 = <4185000 100>, <4113000 95>, <4066000 90>;
|
||||
/* table for 0 degree Celsius */
|
||||
ocv-capacity-table-1 = <4200000 100>, <4185000 95>, <4113000 90>;
|
||||
/* table for 10 degree Celsius */
|
||||
ocv-capacity-table-2 = <4250000 100>, <4200000 95>, <4185000 90>;
|
||||
resistance-temp-table = <20 100>, <10 90>, <0 80>, <(-10) 60>;
|
||||
};
|
||||
|
||||
charger@11 {
|
||||
reg = <0x11>;
|
||||
monitored-battery = <&battery>;
|
||||
};
|
||||
|
||||
fuel-gauge@22 {
|
||||
reg = <0x22>;
|
||||
monitored-battery = <&battery>;
|
||||
};
|
||||
};
|
Загрузка…
Ссылка в новой задаче