thermal: imx: correct driver load sequence for cpu cooling

thermal driver should be regisetered after cpufreq driver has
been registered and probed. Doing so is to make sure that thermal
driver can get the max cpu cooling states correctly when calling
get_property.

Signed-off-by: Bai Ping <b51503@freescale.com>
Signed-off-by: Eduardo Valentin <edubezval@gmail.com>
This commit is contained in:
Bai Ping 2014-10-14 13:12:07 +08:00 коммит произвёл Eduardo Valentin
Родитель 225112a569
Коммит 491b079db3
1 изменённых файлов: 4 добавлений и 0 удалений

Просмотреть файл

@ -459,6 +459,10 @@ static int imx_thermal_probe(struct platform_device *pdev)
int measure_freq;
int ret;
if (!cpufreq_get_current_driver()) {
dev_dbg(&pdev->dev, "no cpufreq driver!");
return -EPROBE_DEFER;
}
data = devm_kzalloc(&pdev->dev, sizeof(*data), GFP_KERNEL);
if (!data)