staging:iio:documentation pull a few sysfs entries out of main docs.

These two attributes are only used in the one driver.  Whilst they
are fairly general I'm not entirely happy committing to them at
this stage.

Signed-off-by: Jonathan Cameron <jic23@kernel.org>
Signed-off-by: Greg Kroah-Hartman <gregkh@linuxfoundation.org>
This commit is contained in:
Jonathan Cameron 2012-04-25 15:54:56 +01:00 коммит произвёл Greg Kroah-Hartman
Родитель 8dc245970a
Коммит 49c36dffbd
2 изменённых файлов: 20 добавлений и 21 удалений

Просмотреть файл

@ -728,24 +728,3 @@ Contact: linux-iio@vger.kernel.org
Description: Description:
This attribute is used to read the amount of quadrature error This attribute is used to read the amount of quadrature error
present in the device at a given time. present in the device at a given time.
What: /sys/.../iio:deviceX/ac_excitation_en
KernelVersion: 3.1.0
Contact: linux-iio@vger.kernel.org
Description:
This attribute, if available, is used to enable the AC
excitation mode found on some converters. In ac excitation mode,
the polarity of the excitation voltage is reversed on
alternate cycles, to eliminate DC errors.
What: /sys/.../iio:deviceX/bridge_switch_en
KernelVersion: 3.1.0
Contact: linux-iio@vger.kernel.org
Description:
This attribute, if available, is used to close or open the
bridge power down switch found on some converters.
In bridge applications, such as strain gauges and load cells,
the bridge itself consumes the majority of the current in the
system. To minimize the current consumption of the system,
the bridge can be disconnected (when it is not being used
using the bridge_switch_en attribute.

Просмотреть файл

@ -0,0 +1,20 @@
What: /sys/.../iio:deviceX/ac_excitation_en
KernelVersion: 3.1.0
Contact: linux-iio@vger.kernel.org
Description:
This attribute, if available, is used to enable the AC
excitation mode found on some converters. In ac excitation mode,
the polarity of the excitation voltage is reversed on
alternate cycles, to eliminate DC errors.
What: /sys/.../iio:deviceX/bridge_switch_en
KernelVersion: 3.1.0
Contact: linux-iio@vger.kernel.org
Description:
This attribute, if available, is used to close or open the
bridge power down switch found on some converters.
In bridge applications, such as strain gauges and load cells,
the bridge itself consumes the majority of the current in the
system. To minimize the current consumption of the system,
the bridge can be disconnected (when it is not being used
using the bridge_switch_en attribute.