perf script: Support physical address
Display the physical address at the tail if it is available. Signed-off-by: Kan Liang <kan.liang@intel.com> Tested-by: Jiri Olsa <jolsa@redhat.com> Acked-by: Stephane Eranian <eranian@google.com> Cc: Andi Kleen <ak@linux.intel.com> Cc: Madhavan Srinivasan <maddy@linux.vnet.ibm.com> Cc: Peter Zijlstra <peterz@infradead.org> Cc: Thomas Gleixner <tglx@linutronix.de> Link: http://lkml.kernel.org/r/1504026672-7304-5-git-send-email-kan.liang@intel.com Signed-off-by: Arnaldo Carvalho de Melo <acme@redhat.com>
This commit is contained in:
Родитель
c35aeb9dfe
Коммит
49d58f04eb
|
@ -117,7 +117,7 @@ OPTIONS
|
|||
Comma separated list of fields to print. Options are:
|
||||
comm, tid, pid, time, cpu, event, trace, ip, sym, dso, addr, symoff,
|
||||
srcline, period, iregs, brstack, brstacksym, flags, bpf-output, brstackinsn, brstackoff,
|
||||
callindent, insn, insnlen, synth.
|
||||
callindent, insn, insnlen, synth, phys_addr.
|
||||
Field list can be prepended with the type, trace, sw or hw,
|
||||
to indicate to which event type the field list applies.
|
||||
e.g., -F sw:comm,tid,time,ip,sym and -F trace:time,cpu,trace
|
||||
|
|
|
@ -87,6 +87,7 @@ enum perf_output_field {
|
|||
PERF_OUTPUT_BRSTACKINSN = 1U << 23,
|
||||
PERF_OUTPUT_BRSTACKOFF = 1U << 24,
|
||||
PERF_OUTPUT_SYNTH = 1U << 25,
|
||||
PERF_OUTPUT_PHYS_ADDR = 1U << 26,
|
||||
};
|
||||
|
||||
struct output_option {
|
||||
|
@ -119,6 +120,7 @@ struct output_option {
|
|||
{.str = "brstackinsn", .field = PERF_OUTPUT_BRSTACKINSN},
|
||||
{.str = "brstackoff", .field = PERF_OUTPUT_BRSTACKOFF},
|
||||
{.str = "synth", .field = PERF_OUTPUT_SYNTH},
|
||||
{.str = "phys_addr", .field = PERF_OUTPUT_PHYS_ADDR},
|
||||
};
|
||||
|
||||
enum {
|
||||
|
@ -175,7 +177,8 @@ static struct {
|
|||
PERF_OUTPUT_EVNAME | PERF_OUTPUT_IP |
|
||||
PERF_OUTPUT_SYM | PERF_OUTPUT_DSO |
|
||||
PERF_OUTPUT_PERIOD | PERF_OUTPUT_ADDR |
|
||||
PERF_OUTPUT_DATA_SRC | PERF_OUTPUT_WEIGHT,
|
||||
PERF_OUTPUT_DATA_SRC | PERF_OUTPUT_WEIGHT |
|
||||
PERF_OUTPUT_PHYS_ADDR,
|
||||
|
||||
.invalid_fields = PERF_OUTPUT_TRACE | PERF_OUTPUT_BPF_OUTPUT,
|
||||
},
|
||||
|
@ -382,6 +385,11 @@ static int perf_evsel__check_attr(struct perf_evsel *evsel,
|
|||
PERF_OUTPUT_IREGS))
|
||||
return -EINVAL;
|
||||
|
||||
if (PRINT_FIELD(PHYS_ADDR) &&
|
||||
perf_evsel__check_stype(evsel, PERF_SAMPLE_PHYS_ADDR, "PHYS_ADDR",
|
||||
PERF_OUTPUT_PHYS_ADDR))
|
||||
return -EINVAL;
|
||||
|
||||
return 0;
|
||||
}
|
||||
|
||||
|
@ -1446,6 +1454,9 @@ static void process_event(struct perf_script *script,
|
|||
if (perf_evsel__is_bpf_output(evsel) && PRINT_FIELD(BPF_OUTPUT))
|
||||
print_sample_bpf_output(sample);
|
||||
print_insn(sample, attr, thread, machine);
|
||||
|
||||
if (PRINT_FIELD(PHYS_ADDR))
|
||||
printf("%16" PRIx64, sample->phys_addr);
|
||||
printf("\n");
|
||||
}
|
||||
|
||||
|
@ -2729,7 +2740,7 @@ int cmd_script(int argc, const char **argv)
|
|||
"Valid types: hw,sw,trace,raw,synth. "
|
||||
"Fields: comm,tid,pid,time,cpu,event,trace,ip,sym,dso,"
|
||||
"addr,symoff,period,iregs,brstack,brstacksym,flags,"
|
||||
"bpf-output,callindent,insn,insnlen,brstackinsn,synth",
|
||||
"bpf-output,callindent,insn,insnlen,brstackinsn,synth,phys_addr",
|
||||
parse_output_fields),
|
||||
OPT_BOOLEAN('a', "all-cpus", &system_wide,
|
||||
"system-wide collection from all CPUs"),
|
||||
|
|
Загрузка…
Ссылка в новой задаче