hwmon: (adt7475) set start bit in probe
The ADT7475 and ADT7476 have the STRT bit cleared by default[1]. Before any monitoring activities the STRT bit needs to be set. Logically this needs to happen before any of the sensors are read so the probe() function seems the best place for it. [1] - https://www.onsemi.com/pub/Collateral/ADT7475-D.PDF Signed-off-by: Chris Packham <chris.packham@alliedtelesis.co.nz> Signed-off-by: Guenter Roeck <linux@roeck-us.net>
This commit is contained in:
Родитель
bdaf9c40b2
Коммит
4abdf38d20
|
@ -59,6 +59,8 @@
|
|||
#define REG_VENDID 0x3E
|
||||
#define REG_DEVID2 0x3F
|
||||
|
||||
#define REG_CONFIG1 0x40
|
||||
|
||||
#define REG_STATUS1 0x41
|
||||
#define REG_STATUS2 0x42
|
||||
|
||||
|
@ -1371,6 +1373,17 @@ static int adt7475_probe(struct i2c_client *client,
|
|||
for (i = 0; i < ADT7475_PWM_COUNT; i++)
|
||||
adt7475_read_pwm(client, i);
|
||||
|
||||
/* Start monitoring */
|
||||
switch (chip) {
|
||||
case adt7475:
|
||||
case adt7476:
|
||||
i2c_smbus_write_byte_data(client, REG_CONFIG1,
|
||||
adt7475_read(REG_CONFIG1) | 0x01);
|
||||
break;
|
||||
default:
|
||||
break;
|
||||
}
|
||||
|
||||
ret = sysfs_create_group(&client->dev.kobj, &adt7475_attr_group);
|
||||
if (ret)
|
||||
return ret;
|
||||
|
|
Загрузка…