mac80211: Requeue work after scan complete for all VIF types.
During a sw scan ieee80211_iface_work ignores work items for all vifs. However after the scan complete work is requeued only for STA, ADHOC and MESH iftypes. This occasionally results in event processing getting delayed/not processed for iftype AP when it coexists with a STA. This can result in data halt and eventually disconnection on the AP interface. Cc: stable@vger.kernel.org Signed-off-by: Sachin Kulkarni <Sachin.Kulkarni@imgtec.com> Signed-off-by: Johannes Berg <johannes.berg@intel.com>
This commit is contained in:
Родитель
da629cf111
Коммит
4fa11ec726
|
@ -1733,7 +1733,6 @@ void ieee80211_ibss_notify_scan_completed(struct ieee80211_local *local)
|
|||
if (sdata->vif.type != NL80211_IFTYPE_ADHOC)
|
||||
continue;
|
||||
sdata->u.ibss.last_scan_completed = jiffies;
|
||||
ieee80211_queue_work(&local->hw, &sdata->work);
|
||||
}
|
||||
mutex_unlock(&local->iflist_mtx);
|
||||
}
|
||||
|
|
|
@ -1370,17 +1370,6 @@ out:
|
|||
sdata_unlock(sdata);
|
||||
}
|
||||
|
||||
void ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local)
|
||||
{
|
||||
struct ieee80211_sub_if_data *sdata;
|
||||
|
||||
rcu_read_lock();
|
||||
list_for_each_entry_rcu(sdata, &local->interfaces, list)
|
||||
if (ieee80211_vif_is_mesh(&sdata->vif) &&
|
||||
ieee80211_sdata_running(sdata))
|
||||
ieee80211_queue_work(&local->hw, &sdata->work);
|
||||
rcu_read_unlock();
|
||||
}
|
||||
|
||||
void ieee80211_mesh_init_sdata(struct ieee80211_sub_if_data *sdata)
|
||||
{
|
||||
|
|
|
@ -362,14 +362,10 @@ static inline bool mesh_path_sel_is_hwmp(struct ieee80211_sub_if_data *sdata)
|
|||
return sdata->u.mesh.mesh_pp_id == IEEE80211_PATH_PROTOCOL_HWMP;
|
||||
}
|
||||
|
||||
void ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local);
|
||||
|
||||
void mesh_path_flush_by_iface(struct ieee80211_sub_if_data *sdata);
|
||||
void mesh_sync_adjust_tbtt(struct ieee80211_sub_if_data *sdata);
|
||||
void ieee80211s_stop(void);
|
||||
#else
|
||||
static inline void
|
||||
ieee80211_mesh_notify_scan_completed(struct ieee80211_local *local) {}
|
||||
static inline bool mesh_path_sel_is_hwmp(struct ieee80211_sub_if_data *sdata)
|
||||
{ return false; }
|
||||
static inline void mesh_path_flush_by_iface(struct ieee80211_sub_if_data *sdata)
|
||||
|
|
|
@ -4005,8 +4005,6 @@ static void ieee80211_restart_sta_timer(struct ieee80211_sub_if_data *sdata)
|
|||
if (!ieee80211_hw_check(&sdata->local->hw, CONNECTION_MONITOR))
|
||||
ieee80211_queue_work(&sdata->local->hw,
|
||||
&sdata->u.mgd.monitor_work);
|
||||
/* and do all the other regular work too */
|
||||
ieee80211_queue_work(&sdata->local->hw, &sdata->work);
|
||||
}
|
||||
}
|
||||
|
||||
|
|
|
@ -314,6 +314,7 @@ static void __ieee80211_scan_completed(struct ieee80211_hw *hw, bool aborted)
|
|||
bool was_scanning = local->scanning;
|
||||
struct cfg80211_scan_request *scan_req;
|
||||
struct ieee80211_sub_if_data *scan_sdata;
|
||||
struct ieee80211_sub_if_data *sdata;
|
||||
|
||||
lockdep_assert_held(&local->mtx);
|
||||
|
||||
|
@ -373,7 +374,16 @@ static void __ieee80211_scan_completed(struct ieee80211_hw *hw, bool aborted)
|
|||
|
||||
ieee80211_mlme_notify_scan_completed(local);
|
||||
ieee80211_ibss_notify_scan_completed(local);
|
||||
ieee80211_mesh_notify_scan_completed(local);
|
||||
|
||||
/* Requeue all the work that might have been ignored while
|
||||
* the scan was in progress; if there was none this will
|
||||
* just be a no-op for the particular interface.
|
||||
*/
|
||||
list_for_each_entry_rcu(sdata, &local->interfaces, list) {
|
||||
if (ieee80211_sdata_running(sdata))
|
||||
ieee80211_queue_work(&sdata->local->hw, &sdata->work);
|
||||
}
|
||||
|
||||
if (was_scanning)
|
||||
ieee80211_start_next_roc(local);
|
||||
}
|
||||
|
|
Загрузка…
Ссылка в новой задаче