drm/tegra: dc - Do not touch power control register

Setting the bits in this register is dependent on the output type driven
by the display controller. All output drivers already set these properly
so there is no need to do it here again.

Signed-off-by: Thierry Reding <treding@nvidia.com>
This commit is contained in:
Thierry Reding 2014-04-16 09:52:31 +02:00
Родитель 10288eea88
Коммит 501bcbd1b2
1 изменённых файлов: 0 добавлений и 4 удалений

Просмотреть файл

@ -743,10 +743,6 @@ static void tegra_crtc_prepare(struct drm_crtc *crtc)
WIN_A_OF_INT | WIN_B_OF_INT | WIN_C_OF_INT;
tegra_dc_writel(dc, value, DC_CMD_INT_POLARITY);
value = PW0_ENABLE | PW1_ENABLE | PW2_ENABLE | PW3_ENABLE |
PW4_ENABLE | PM0_ENABLE | PM1_ENABLE;
tegra_dc_writel(dc, value, DC_CMD_DISPLAY_POWER_CONTROL);
/* initialize timer */
value = CURSOR_THRESHOLD(0) | WINDOW_A_THRESHOLD(0x20) |
WINDOW_B_THRESHOLD(0x20) | WINDOW_C_THRESHOLD(0x20);