mlx4_core: Workaround firmware bug in query dev cap
ConnectX firmware is supposed to report the number blue flame registers per page as log2 of the value. However, due to a firmware bug, it reports actual number. This patch works around this by checking if the number of registers calculated fits within a page. If it does not, we use 8 registers per page. Signed-off-by: Eli Cohen <eli@mellanox.co.il> Signed-off-by: Roland Dreier <rolandd@cisco.com>
This commit is contained in:
Родитель
e27535b9c6
Коммит
58d74bb1d9
|
@ -289,6 +289,10 @@ int mlx4_QUERY_DEV_CAP(struct mlx4_dev *dev, struct mlx4_dev_cap *dev_cap)
|
|||
MLX4_GET(field, outbox, QUERY_DEV_CAP_LOG_BF_REG_SZ_OFFSET);
|
||||
dev_cap->bf_reg_size = 1 << (field & 0x1f);
|
||||
MLX4_GET(field, outbox, QUERY_DEV_CAP_LOG_MAX_BF_REGS_PER_PAGE_OFFSET);
|
||||
if ((1 << (field & 0x3f)) > (PAGE_SIZE / dev_cap->bf_reg_size)) {
|
||||
mlx4_warn(dev, "firmware bug: log2 # of blue flame regs is invalid (%d), forcing 3\n", field & 0x1f);
|
||||
field = 3;
|
||||
}
|
||||
dev_cap->bf_regs_per_page = 1 << (field & 0x3f);
|
||||
mlx4_dbg(dev, "BlueFlame available (reg size %d, regs/page %d)\n",
|
||||
dev_cap->bf_reg_size, dev_cap->bf_regs_per_page);
|
||||
|
|