[MTD] [NAND] pxa3xx: convert from ns to clock ticks more accurately

The various fields in NDTR{01} are in units of clock ticks minus one, but the
ns2cycle macro mistakenly adds one, inflating the number of clock ticks and
making it impossible to set any of these fields to zero.

Signed-off-by: Matt Reimer <mreimer@vpop.net>
Signed-off-by: Eric Miao <eric.miao@marvell.com>
Signed-off-by: David Woodhouse <David.Woodhouse@intel.com>
This commit is contained in:
Matt Reimer 2008-11-18 10:54:32 -08:00 коммит произвёл David Woodhouse
Родитель 7f9938d0fd
Коммит 5b0d4d7c8a
1 изменённых файлов: 1 добавлений и 1 удалений

Просмотреть файл

@ -298,7 +298,7 @@ static struct pxa3xx_nand_flash *builtin_flash_types[] = {
#define NDTR1_tAR(c) (min((c), 15) << 0)
/* convert nano-seconds to nand flash controller clock cycles */
#define ns2cycle(ns, clk) (int)(((ns) * (clk / 1000000) / 1000) + 1)
#define ns2cycle(ns, clk) (int)(((ns) * (clk / 1000000) / 1000) - 1)
static void pxa3xx_nand_set_timing(struct pxa3xx_nand_info *info,
const struct pxa3xx_nand_timing *t)