net/mlx4_en: Set correct port parameters during device initialization
Set valid port parameters: MTU and flow control configuration when configuring the port during HW device initialization, prior to the net device open() being called. Using invalid parameters (such as all zeros) could lead to bad firmware behavior. Signed-off-by: Yevgeny Petrilin <yevgenyp@mellanox.co.il> Signed-off-by: David S. Miller <davem@davemloft.net>
This commit is contained in:
Родитель
6de0298ec9
Коммит
5c8e904666
|
@ -1204,9 +1204,11 @@ int mlx4_en_init_netdev(struct mlx4_en_dev *mdev, int port,
|
|||
en_warn(priv, "Using %d RX rings\n", prof->rx_ring_num);
|
||||
|
||||
/* Configure port */
|
||||
mlx4_en_calc_rx_buf(dev);
|
||||
err = mlx4_SET_PORT_general(mdev->dev, priv->port,
|
||||
MLX4_EN_MIN_MTU,
|
||||
0, 0, 0, 0);
|
||||
priv->rx_skb_size + ETH_FCS_LEN,
|
||||
prof->tx_pause, prof->tx_ppp,
|
||||
prof->rx_pause, prof->rx_ppp);
|
||||
if (err) {
|
||||
en_err(priv, "Failed setting port general configurations "
|
||||
"for port %d, with error %d\n", priv->port, err);
|
||||
|
|