md/raid5: prefer replacing failed devices over want-replacement devices.
If a RAID5 has both a failed device and a device marked as 'WantReplacement', then we should preferentially replace the failed device. However the current code replaces whichever is found first. So split into 2 loops, check fail failed/missing first, and only check for WantReplacement if nothing is failed or missing. Reported-by: majianpeng <majianpeng@gmail.com> Signed-off-by: NeilBrown <neilb@suse.de>
This commit is contained in:
Родитель
fc448a18ae
Коммит
5cfb22a1f8
|
@ -5465,10 +5465,9 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev)
|
|||
if (rdev->saved_raid_disk >= 0 &&
|
||||
rdev->saved_raid_disk >= first &&
|
||||
conf->disks[rdev->saved_raid_disk].rdev == NULL)
|
||||
disk = rdev->saved_raid_disk;
|
||||
else
|
||||
disk = first;
|
||||
for ( ; disk <= last ; disk++) {
|
||||
first = rdev->saved_raid_disk;
|
||||
|
||||
for (disk = first; disk <= last; disk++) {
|
||||
p = conf->disks + disk;
|
||||
if (p->rdev == NULL) {
|
||||
clear_bit(In_sync, &rdev->flags);
|
||||
|
@ -5477,8 +5476,11 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev)
|
|||
if (rdev->saved_raid_disk != disk)
|
||||
conf->fullsync = 1;
|
||||
rcu_assign_pointer(p->rdev, rdev);
|
||||
break;
|
||||
goto out;
|
||||
}
|
||||
}
|
||||
for (disk = first; disk <= last; disk++) {
|
||||
p = conf->disks + disk;
|
||||
if (test_bit(WantReplacement, &p->rdev->flags) &&
|
||||
p->replacement == NULL) {
|
||||
clear_bit(In_sync, &rdev->flags);
|
||||
|
@ -5490,6 +5492,7 @@ static int raid5_add_disk(struct mddev *mddev, struct md_rdev *rdev)
|
|||
break;
|
||||
}
|
||||
}
|
||||
out:
|
||||
print_raid5_conf(conf);
|
||||
return err;
|
||||
}
|
||||
|
|
Загрузка…
Ссылка в новой задаче