pwm: pwm-samsung: Trigger manual update when disabling PWM

When duty-cycle is at full level (100%), the TCNTn and TCMPn registers
needs to be flushed in order to disable the signal. The PWM manual does
not say anything about this, but states that only clearing the TCON
auto-reload bit should be needed, and this seems to be true when the PWM
duty-cycle is not at full level. This can be observed on an Axis
ARTPEC-8, by running:

  echo <period> > pwm/period
  echo <period> > pwm/duty_cycle
  echo 1 > pwm/enable
  echo 0 > pwm/enable

Since the TCNTn and TCMPn registers are activated when enabling the PWM
(setting TCON auto-reload bit), and are not touched when disabling the
PWM, the double buffered auto-reload function seems to be still active.
Lowering duty-cycle, and restoring it again in between the enabling and
disabling, makes the disable work since it triggers a reload of the
TCNTn and TCMPn registers.

Fix this by securing a reload of the TCNTn and TCMPn registers when
disabling the PWM and having a full duty-cycle.

Signed-off-by: Mårten Lindahl <marten.lindahl@axis.com>
Reviewed-by: Krzysztof Kozlowski <krzysztof.kozlowski@canonical.com>
Acked-by: Uwe Kleine-König <u.kleine-koenig@pengutronix.de>
Signed-off-by: Thierry Reding <thierry.reding@gmail.com>
This commit is contained in:
Mårten Lindahl 2021-09-09 12:10:42 +02:00 коммит произвёл Thierry Reding
Родитель 6facd84083
Коммит 5d82e66139
1 изменённых файлов: 22 добавлений и 8 удалений

Просмотреть файл

@ -117,6 +117,20 @@ static inline unsigned int to_tcon_channel(unsigned int channel)
return (channel == 0) ? 0 : (channel + 1);
}
static void __pwm_samsung_manual_update(struct samsung_pwm_chip *chip,
struct pwm_device *pwm)
{
unsigned int tcon_chan = to_tcon_channel(pwm->hwpwm);
u32 tcon;
tcon = readl(chip->base + REG_TCON);
tcon |= TCON_MANUALUPDATE(tcon_chan);
writel(tcon, chip->base + REG_TCON);
tcon &= ~TCON_MANUALUPDATE(tcon_chan);
writel(tcon, chip->base + REG_TCON);
}
static void pwm_samsung_set_divisor(struct samsung_pwm_chip *pwm,
unsigned int channel, u8 divisor)
{
@ -276,6 +290,13 @@ static void pwm_samsung_disable(struct pwm_chip *chip, struct pwm_device *pwm)
tcon &= ~TCON_AUTORELOAD(tcon_chan);
writel(tcon, our_chip->base + REG_TCON);
/*
* In case the PWM is at 100% duty cycle, force a manual
* update to prevent the signal from staying high.
*/
if (readl(our_chip->base + REG_TCMPB(pwm->hwpwm)) == (u32)-1U)
__pwm_samsung_manual_update(our_chip, pwm);
our_chip->disabled_mask |= BIT(pwm->hwpwm);
spin_unlock_irqrestore(&samsung_pwm_lock, flags);
@ -284,18 +305,11 @@ static void pwm_samsung_disable(struct pwm_chip *chip, struct pwm_device *pwm)
static void pwm_samsung_manual_update(struct samsung_pwm_chip *chip,
struct pwm_device *pwm)
{
unsigned int tcon_chan = to_tcon_channel(pwm->hwpwm);
u32 tcon;
unsigned long flags;
spin_lock_irqsave(&samsung_pwm_lock, flags);
tcon = readl(chip->base + REG_TCON);
tcon |= TCON_MANUALUPDATE(tcon_chan);
writel(tcon, chip->base + REG_TCON);
tcon &= ~TCON_MANUALUPDATE(tcon_chan);
writel(tcon, chip->base + REG_TCON);
__pwm_samsung_manual_update(chip, pwm);
spin_unlock_irqrestore(&samsung_pwm_lock, flags);
}