powerpc/64s: Fix unnecessary machine check handler relocation branch

Similarly to commit 2563a70c3b ("powerpc/64s: Remove unnecessary relocation
branch from idle handler"), the machine check handler has a BRANCH_TO from
relocated to relocated code, which is unnecessary.

It has also caused build errors with some toolchains:

  arch/powerpc/kernel/exceptions-64s.S: Assembler messages:
  arch/powerpc/kernel/exceptions-64s.S:395: Error: operand out of range
  (0xffffffffffff8280 is not between 0x0000000000000000 and
  0x000000000000ffff)

Fixes: 1945bc4549 ("powerpc/64s: Fix POWER9 machine check handler from stop state")
Signed-off-by: Nicholas Piggin <npiggin@gmail.com>
Reported-and-tested-by : Abdul Haleem <abdhalee@linux.vnet.ibm.com>
Signed-off-by: Michael Ellerman <mpe@ellerman.id.au>
This commit is contained in:
Nicholas Piggin 2017-05-04 20:41:12 +10:00 коммит произвёл Michael Ellerman
Родитель ba95b5d035
Коммит 6102c005a7
1 изменённых файлов: 1 добавлений и 3 удалений

Просмотреть файл

@ -391,9 +391,7 @@ EXC_COMMON_BEGIN(machine_check_handle_early)
*/
BEGIN_FTR_SECTION
rlwinm. r11,r12,47-31,30,31
beq- 4f
BRANCH_TO_COMMON(r10, machine_check_idle_common)
4:
bne machine_check_idle_common
END_FTR_SECTION_IFSET(CPU_FTR_HVMODE | CPU_FTR_ARCH_206)
#endif