HID: wacom: Delete unnecessary checks before the function call "input_free_device"

The input_free_device() function tests whether its argument is NULL and
then returns immediately. Thus the test around the call is not needed.

This issue was detected by using the Coccinelle software.

Signed-off-by: Markus Elfring <elfring@users.sourceforge.net>
Signed-off-by: Jiri Kosina <jkosina@suse.com>
This commit is contained in:
Markus Elfring 2015-07-09 08:08:15 +02:00 коммит произвёл Jiri Kosina
Родитель 615322f6ac
Коммит 67e123ff0e
1 изменённых файлов: 3 добавлений и 6 удалений

Просмотреть файл

@ -1149,12 +1149,9 @@ static void wacom_free_inputs(struct wacom *wacom)
{
struct wacom_wac *wacom_wac = &(wacom->wacom_wac);
if (wacom_wac->pen_input)
input_free_device(wacom_wac->pen_input);
if (wacom_wac->touch_input)
input_free_device(wacom_wac->touch_input);
if (wacom_wac->pad_input)
input_free_device(wacom_wac->pad_input);
input_free_device(wacom_wac->pen_input);
input_free_device(wacom_wac->touch_input);
input_free_device(wacom_wac->pad_input);
wacom_wac->pen_input = NULL;
wacom_wac->touch_input = NULL;
wacom_wac->pad_input = NULL;