Thermal: Add documentation for platform layer data
This patch adds documentation for thermal_bind_params and thermal_zone_params structures. Also, adds details on EXPORT_SYMBOL APIs. Signed-off-by: Durgadoss R <durgadoss.r@intel.com> Signed-off-by: Zhang Rui <rui.zhang@intel.com>
This commit is contained in:
Родитель
f2b4caafd4
Коммит
6ea083b18d
|
@ -112,6 +112,29 @@ temperature) and throttle appropriate devices.
|
|||
trip: indicates which trip point the cooling devices is associated with
|
||||
in this thermal zone.
|
||||
|
||||
1.4 Thermal Zone Parameters
|
||||
1.4.1 struct thermal_bind_params
|
||||
This structure defines the following parameters that are used to bind
|
||||
a zone with a cooling device for a particular trip point.
|
||||
.cdev: The cooling device pointer
|
||||
.weight: The 'influence' of a particular cooling device on this zone.
|
||||
This is on a percentage scale. The sum of all these weights
|
||||
(for a particular zone) cannot exceed 100.
|
||||
.trip_mask:This is a bit mask that gives the binding relation between
|
||||
this thermal zone and cdev, for a particular trip point.
|
||||
If nth bit is set, then the cdev and thermal zone are bound
|
||||
for trip point n.
|
||||
.match: This call back returns success(0) if the 'tz and cdev' need to
|
||||
be bound, as per platform data.
|
||||
1.4.2 struct thermal_zone_params
|
||||
This structure defines the platform level parameters for a thermal zone.
|
||||
This data, for each thermal zone should come from the platform layer.
|
||||
This is an optional feature where some platforms can choose not to
|
||||
provide this data.
|
||||
.governor_name: Name of the thermal governor used for this zone
|
||||
.num_tbps: Number of thermal_bind_params entries for this zone
|
||||
.tbp: thermal_bind_params entries
|
||||
|
||||
2. sysfs attributes structure
|
||||
|
||||
RO read only value
|
||||
|
@ -126,6 +149,7 @@ Thermal zone device sys I/F, created once it's registered:
|
|||
|---type: Type of the thermal zone
|
||||
|---temp: Current temperature
|
||||
|---mode: Working mode of the thermal zone
|
||||
|---policy: Thermal governor used for this zone
|
||||
|---trip_point_[0-*]_temp: Trip point temperature
|
||||
|---trip_point_[0-*]_type: Trip point type
|
||||
|---trip_point_[0-*]_hyst: Hysteresis value for this trip point
|
||||
|
@ -187,6 +211,10 @@ mode
|
|||
charge of the thermal management.
|
||||
RW, Optional
|
||||
|
||||
policy
|
||||
One of the various thermal governors used for a particular zone.
|
||||
RW, Required
|
||||
|
||||
trip_point_[0-*]_temp
|
||||
The temperature above which trip point will be fired.
|
||||
Unit: millidegree Celsius
|
||||
|
@ -264,6 +292,7 @@ method, the sys I/F structure will be built like this:
|
|||
|---type: acpitz
|
||||
|---temp: 37000
|
||||
|---mode: enabled
|
||||
|---policy: step_wise
|
||||
|---trip_point_0_temp: 100000
|
||||
|---trip_point_0_type: critical
|
||||
|---trip_point_1_temp: 80000
|
||||
|
@ -305,3 +334,38 @@ to a thermal_zone_device when it registers itself with the framework. The
|
|||
event will be one of:{THERMAL_AUX0, THERMAL_AUX1, THERMAL_CRITICAL,
|
||||
THERMAL_DEV_FAULT}. Notification can be sent when the current temperature
|
||||
crosses any of the configured thresholds.
|
||||
|
||||
5. Export Symbol APIs:
|
||||
|
||||
5.1: get_tz_trend:
|
||||
This function returns the trend of a thermal zone, i.e the rate of change
|
||||
of temperature of the thermal zone. Ideally, the thermal sensor drivers
|
||||
are supposed to implement the callback. If they don't, the thermal
|
||||
framework calculated the trend by comparing the previous and the current
|
||||
temperature values.
|
||||
|
||||
5.2:get_thermal_instance:
|
||||
This function returns the thermal_instance corresponding to a given
|
||||
{thermal_zone, cooling_device, trip_point} combination. Returns NULL
|
||||
if such an instance does not exist.
|
||||
|
||||
5.3:notify_thermal_framework:
|
||||
This function handles the trip events from sensor drivers. It starts
|
||||
throttling the cooling devices according to the policy configured.
|
||||
For CRITICAL and HOT trip points, this notifies the respective drivers,
|
||||
and does actual throttling for other trip points i.e ACTIVE and PASSIVE.
|
||||
The throttling policy is based on the configured platform data; if no
|
||||
platform data is provided, this uses the step_wise throttling policy.
|
||||
|
||||
5.4:thermal_cdev_update:
|
||||
This function serves as an arbitrator to set the state of a cooling
|
||||
device. It sets the cooling device to the deepest cooling state if
|
||||
possible.
|
||||
|
||||
5.5:thermal_register_governor:
|
||||
This function lets the various thermal governors to register themselves
|
||||
with the Thermal framework. At run time, depending on a zone's platform
|
||||
data, a particular governor is used for throttling.
|
||||
|
||||
5.6:thermal_unregister_governor:
|
||||
This function unregisters a governor from the thermal framework.
|
||||
|
|
Загрузка…
Ссылка в новой задаче