iio: mma8452: Use correct acceleration units.
The userspace interface for acceleration sensors is documented as using m/s^2 units [Documentation/ABI/testing/sysfs-bus-iio] The fullscale raw value for the mma8452 (-2048) corresponds to -2G, -4G or -8G depending on the seleted mode. The scale table was converting to G rather than m/s^2. Change the scaling table to match the documented interface. Signed-off-by: Martin Fuzzey <mfuzzey@parkeon.com> Signed-off-by: Jonathan Cameron <jic23@kernel.org> Cc: stable@vger.kernel.org
This commit is contained in:
Родитель
78b3321610
Коммит
71702e6e52
|
@ -111,8 +111,14 @@ static const int mma8452_samp_freq[8][2] = {
|
|||
{6, 250000}, {1, 560000}
|
||||
};
|
||||
|
||||
/*
|
||||
* Hardware has fullscale of -2G, -4G, -8G corresponding to raw value -2048
|
||||
* The userspace interface uses m/s^2 and we declare micro units
|
||||
* So scale factor is given by:
|
||||
* g * N * 1000000 / 2048 for N = 2, 4, 8 and g=9.80665
|
||||
*/
|
||||
static const int mma8452_scales[3][2] = {
|
||||
{0, 977}, {0, 1953}, {0, 3906}
|
||||
{0, 9577}, {0, 19154}, {0, 38307}
|
||||
};
|
||||
|
||||