regulator: twl-regulator: fix n_voltages for twl6030 variable LDOs
The n_voltages initializer for the TWL6030_ADJUSTABLE_LDO macro is off by one, causing the the highest supported voltage to be unreachable. Setting the machine constraints to only allow the highest voltage causes errors: machine_constraints_voltage: VAUX3_6030: unsupportable voltage constraints twl_reg twl_reg.39: can't register VAUX3_6030, -22 twl_reg: probe of twl_reg.39 failed with error -22 This patch fixes the off by one error. Tested by setting VAUX3_6030 to 3.3V. Signed-off-by: Colin Cross <ccross@android.com> Acked-by: Mark Brown <broonie@opensource.wolfsonmicro.com> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This commit is contained in:
Родитель
2ae3636b79
Коммит
7736f11dba
|
@ -864,7 +864,7 @@ static struct regulator_ops twlsmps_ops = {
|
|||
.desc = { \
|
||||
.name = #label, \
|
||||
.id = TWL6030_REG_##label, \
|
||||
.n_voltages = (max_mVolts - min_mVolts)/100, \
|
||||
.n_voltages = (max_mVolts - min_mVolts)/100 + 1, \
|
||||
.ops = &twl6030ldo_ops, \
|
||||
.type = REGULATOR_VOLTAGE, \
|
||||
.owner = THIS_MODULE, \
|
||||
|
|