cpufreq: cpufreq-cpu0: add dt node parsing for cooling device properties
This patch changes the cpufreq-cpu0 driver to consider if a cpu needs cooling (with cpufreq). In case the cooling is needed, the cpu0 device tree node needs to be properly configured with cooling device properties. In case these properties are present,, the driver will load a cpufreq cooling device in the system. The cpufreq-cpu0 driver is not interested in determining how the system should be using the cooling device. The driver is responsible only of loading the cooling device. Describing how the cooling device will be used can be accomplished by setting up a thermal zone that references and is composed by the cpufreq cooling device. Cc: "Rafael J. Wysocki" <rjw@sisk.pl> Cc: Grant Likely <grant.likely@linaro.org> Cc: Rob Herring <rob.herring@calxeda.com> Cc: cpufreq@vger.kernel.org Cc: linux-pm@vger.kernel.org Cc: linux-kernel@vger.kernel.org Cc: devicetree-discuss@lists.ozlabs.org Acked-by: Viresh Kumar <viresh.kumar@linaro.org> Signed-off-by: Eduardo Valentin <eduardo.valentin@ti.com>
This commit is contained in:
Родитель
39d99cff76
Коммит
77cff5926a
|
@ -15,6 +15,10 @@ Optional properties:
|
|||
- clock-latency: Specify the possible maximum transition latency for clock,
|
||||
in unit of nanoseconds.
|
||||
- voltage-tolerance: Specify the CPU voltage tolerance in percentage.
|
||||
- #cooling-cells:
|
||||
- cooling-min-level:
|
||||
- cooling-max-level:
|
||||
Please refer to Documentation/devicetree/bindings/thermal/thermal.txt.
|
||||
|
||||
Examples:
|
||||
|
||||
|
@ -33,6 +37,9 @@ cpus {
|
|||
198000 850000
|
||||
>;
|
||||
clock-latency = <61036>; /* two CLK32 periods */
|
||||
#cooling-cells = <2>;
|
||||
cooling-min-level = <0>;
|
||||
cooling-max-level = <2>;
|
||||
};
|
||||
|
||||
cpu@1 {
|
||||
|
|
|
@ -181,7 +181,7 @@ config CPU_FREQ_GOV_CONSERVATIVE
|
|||
|
||||
config GENERIC_CPUFREQ_CPU0
|
||||
tristate "Generic CPU0 cpufreq driver"
|
||||
depends on HAVE_CLK && REGULATOR && PM_OPP && OF
|
||||
depends on HAVE_CLK && REGULATOR && PM_OPP && OF && THERMAL && CPU_THERMAL
|
||||
help
|
||||
This adds a generic cpufreq driver for CPU0 frequency management.
|
||||
It supports both uniprocessor (UP) and symmetric multiprocessor (SMP)
|
||||
|
|
|
@ -13,7 +13,9 @@
|
|||
|
||||
#include <linux/clk.h>
|
||||
#include <linux/cpu.h>
|
||||
#include <linux/cpu_cooling.h>
|
||||
#include <linux/cpufreq.h>
|
||||
#include <linux/cpumask.h>
|
||||
#include <linux/err.h>
|
||||
#include <linux/module.h>
|
||||
#include <linux/of.h>
|
||||
|
@ -21,6 +23,7 @@
|
|||
#include <linux/platform_device.h>
|
||||
#include <linux/regulator/consumer.h>
|
||||
#include <linux/slab.h>
|
||||
#include <linux/thermal.h>
|
||||
|
||||
static unsigned int transition_latency;
|
||||
static unsigned int voltage_tolerance; /* in percentage */
|
||||
|
@ -29,6 +32,7 @@ static struct device *cpu_dev;
|
|||
static struct clk *cpu_clk;
|
||||
static struct regulator *cpu_reg;
|
||||
static struct cpufreq_frequency_table *freq_table;
|
||||
static struct thermal_cooling_device *cdev;
|
||||
|
||||
static unsigned int cpu0_get_speed(unsigned int cpu)
|
||||
{
|
||||
|
@ -201,6 +205,17 @@ static int cpu0_cpufreq_probe(struct platform_device *pdev)
|
|||
goto out_free_table;
|
||||
}
|
||||
|
||||
/*
|
||||
* For now, just loading the cooling device;
|
||||
* thermal DT code takes care of matching them.
|
||||
*/
|
||||
if (of_find_property(np, "#cooling-cells", NULL)) {
|
||||
cdev = of_cpufreq_cooling_register(np, cpu_present_mask);
|
||||
if (IS_ERR(cdev))
|
||||
pr_err("running cpufreq without cooling device: %ld\n",
|
||||
PTR_ERR(cdev));
|
||||
}
|
||||
|
||||
of_node_put(np);
|
||||
return 0;
|
||||
|
||||
|
@ -213,6 +228,7 @@ out_put_node:
|
|||
|
||||
static int cpu0_cpufreq_remove(struct platform_device *pdev)
|
||||
{
|
||||
cpufreq_cooling_unregister(cdev);
|
||||
cpufreq_unregister_driver(&cpu0_cpufreq_driver);
|
||||
dev_pm_opp_free_cpufreq_table(cpu_dev, &freq_table);
|
||||
|
||||
|
|