HID: fix autocentering of PID devices
When setting the autocentering of PID devices, PID_DIRECTION_ENABLE is not being explicitely set to 1. This results in autocentering working only on the vertical axis when this field is preset to 0. Fix that by setting it explicitely to 1 when preparing the set_effect report for autocentering spring effect. Signed-off-by: Diogo Kastrup <dk@bighost.com.br> Signed-off-by: Anssi Hannula <anssi.hannula@gmail.com> Signed-off-by: Jiri Kosina <jkosina@suse.cz>
This commit is contained in:
Родитель
ea9a4a8b0e
Коммит
816cbfda8b
|
@ -738,6 +738,7 @@ static void pidff_autocenter(struct pidff_device *pidff, u16 magnitude)
|
|||
pidff->set_effect[PID_TRIGGER_BUTTON].value[0] = 0;
|
||||
pidff->set_effect[PID_TRIGGER_REPEAT_INT].value[0] = 0;
|
||||
pidff_set(&pidff->set_effect[PID_GAIN], magnitude);
|
||||
pidff->set_effect[PID_DIRECTION_ENABLE].value[0] = 1;
|
||||
pidff->set_effect[PID_START_DELAY].value[0] = 0;
|
||||
|
||||
usbhid_submit_report(pidff->hid, pidff->reports[PID_SET_EFFECT],
|
||||
|
|