regulator: add get_status()
Based on previous LKML discussions: * Update docs for regulator sysfs class attributes to highlight the fact that all current attributes are intended to be control inputs, including notably "state" and "opmode" which previously implied otherwise. * Define a new regulator driver get_status() method, which is the first method reporting regulator outputs instead of inputs. It can report on/off and error status; or instead of simply "on", report the actual operating mode. For the moment, this is a sysfs-only interface, not accessible to regulator clients. Such clients can use the current notification interfaces to detect errors, if the regulator reports them. Signed-off-by: David Brownell <dbrownell@users.sourceforge.net> Signed-off-by: Liam Girdwood <lrg@slimlogic.co.uk>
This commit is contained in:
Родитель
93e14baa44
Коммит
853116a105
|
@ -4,8 +4,8 @@ KernelVersion: 2.6.26
|
|||
Contact: Liam Girdwood <lrg@slimlogic.co.uk>
|
||||
Description:
|
||||
Some regulator directories will contain a field called
|
||||
state. This reports the regulator enable status, for
|
||||
regulators which can report that value.
|
||||
state. This reports the regulator enable control, for
|
||||
regulators which can report that input value.
|
||||
|
||||
This will be one of the following strings:
|
||||
|
||||
|
@ -14,16 +14,54 @@ Description:
|
|||
'unknown'
|
||||
|
||||
'enabled' means the regulator output is ON and is supplying
|
||||
power to the system.
|
||||
power to the system (assuming no error prevents it).
|
||||
|
||||
'disabled' means the regulator output is OFF and is not
|
||||
supplying power to the system..
|
||||
supplying power to the system (unless some non-Linux
|
||||
control has enabled it).
|
||||
|
||||
'unknown' means software cannot determine the state, or
|
||||
the reported state is invalid.
|
||||
|
||||
NOTE: this field can be used in conjunction with microvolts
|
||||
and microamps to determine regulator output levels.
|
||||
or microamps to determine configured regulator output levels.
|
||||
|
||||
|
||||
What: /sys/class/regulator/.../status
|
||||
Description:
|
||||
Some regulator directories will contain a field called
|
||||
"status". This reports the current regulator status, for
|
||||
regulators which can report that output value.
|
||||
|
||||
This will be one of the following strings:
|
||||
|
||||
off
|
||||
on
|
||||
error
|
||||
fast
|
||||
normal
|
||||
idle
|
||||
standby
|
||||
|
||||
"off" means the regulator is not supplying power to the
|
||||
system.
|
||||
|
||||
"on" means the regulator is supplying power to the system,
|
||||
and the regulator can't report a detailed operation mode.
|
||||
|
||||
"error" indicates an out-of-regulation status such as being
|
||||
disabled due to thermal shutdown, or voltage being unstable
|
||||
because of problems with the input power supply.
|
||||
|
||||
"fast", "normal", "idle", and "standby" are all detailed
|
||||
regulator operation modes (described elsewhere). They
|
||||
imply "on", but provide more detail.
|
||||
|
||||
Note that regulator status is a function of many inputs,
|
||||
not limited to control inputs from Linux. For example,
|
||||
the actual load presented may trigger "error" status; or
|
||||
a regulator may be enabled by another user, even though
|
||||
Linux did not enable it.
|
||||
|
||||
|
||||
What: /sys/class/regulator/.../type
|
||||
|
@ -58,7 +96,7 @@ Description:
|
|||
Some regulator directories will contain a field called
|
||||
microvolts. This holds the regulator output voltage setting
|
||||
measured in microvolts (i.e. E-6 Volts), for regulators
|
||||
which can report that voltage.
|
||||
which can report the control input for voltage.
|
||||
|
||||
NOTE: This value should not be used to determine the regulator
|
||||
output voltage level as this value is the same regardless of
|
||||
|
@ -73,7 +111,7 @@ Description:
|
|||
Some regulator directories will contain a field called
|
||||
microamps. This holds the regulator output current limit
|
||||
setting measured in microamps (i.e. E-6 Amps), for regulators
|
||||
which can report that current.
|
||||
which can report the control input for a current limit.
|
||||
|
||||
NOTE: This value should not be used to determine the regulator
|
||||
output current level as this value is the same regardless of
|
||||
|
@ -87,7 +125,7 @@ Contact: Liam Girdwood <lrg@slimlogic.co.uk>
|
|||
Description:
|
||||
Some regulator directories will contain a field called
|
||||
opmode. This holds the current regulator operating mode,
|
||||
for regulators which can report it.
|
||||
for regulators which can report that control input value.
|
||||
|
||||
The opmode value can be one of the following strings:
|
||||
|
||||
|
@ -101,7 +139,8 @@ Description:
|
|||
|
||||
NOTE: This value should not be used to determine the regulator
|
||||
output operating mode as this value is the same regardless of
|
||||
whether the regulator is enabled or disabled.
|
||||
whether the regulator is enabled or disabled. A "status"
|
||||
attribute may be available to determine the actual mode.
|
||||
|
||||
|
||||
What: /sys/class/regulator/.../min_microvolts
|
||||
|
|
|
@ -312,6 +312,47 @@ static ssize_t regulator_state_show(struct device *dev,
|
|||
}
|
||||
static DEVICE_ATTR(state, 0444, regulator_state_show, NULL);
|
||||
|
||||
static ssize_t regulator_status_show(struct device *dev,
|
||||
struct device_attribute *attr, char *buf)
|
||||
{
|
||||
struct regulator_dev *rdev = dev_get_drvdata(dev);
|
||||
int status;
|
||||
char *label;
|
||||
|
||||
status = rdev->desc->ops->get_status(rdev);
|
||||
if (status < 0)
|
||||
return status;
|
||||
|
||||
switch (status) {
|
||||
case REGULATOR_STATUS_OFF:
|
||||
label = "off";
|
||||
break;
|
||||
case REGULATOR_STATUS_ON:
|
||||
label = "on";
|
||||
break;
|
||||
case REGULATOR_STATUS_ERROR:
|
||||
label = "error";
|
||||
break;
|
||||
case REGULATOR_STATUS_FAST:
|
||||
label = "fast";
|
||||
break;
|
||||
case REGULATOR_STATUS_NORMAL:
|
||||
label = "normal";
|
||||
break;
|
||||
case REGULATOR_STATUS_IDLE:
|
||||
label = "idle";
|
||||
break;
|
||||
case REGULATOR_STATUS_STANDBY:
|
||||
label = "standby";
|
||||
break;
|
||||
default:
|
||||
return -ERANGE;
|
||||
}
|
||||
|
||||
return sprintf(buf, "%s\n", label);
|
||||
}
|
||||
static DEVICE_ATTR(status, 0444, regulator_status_show, NULL);
|
||||
|
||||
static ssize_t regulator_min_uA_show(struct device *dev,
|
||||
struct device_attribute *attr, char *buf)
|
||||
{
|
||||
|
@ -1744,6 +1785,11 @@ static int add_regulator_attributes(struct regulator_dev *rdev)
|
|||
if (status < 0)
|
||||
return status;
|
||||
}
|
||||
if (ops->get_status) {
|
||||
status = device_create_file(dev, &dev_attr_status);
|
||||
if (status < 0)
|
||||
return status;
|
||||
}
|
||||
|
||||
/* some attributes are type-specific */
|
||||
if (rdev->desc->type == REGULATOR_CURRENT) {
|
||||
|
|
|
@ -21,6 +21,17 @@
|
|||
struct regulator_dev;
|
||||
struct regulator_init_data;
|
||||
|
||||
enum regulator_status {
|
||||
REGULATOR_STATUS_OFF,
|
||||
REGULATOR_STATUS_ON,
|
||||
REGULATOR_STATUS_ERROR,
|
||||
/* fast/normal/idle/standby are flavors of "on" */
|
||||
REGULATOR_STATUS_FAST,
|
||||
REGULATOR_STATUS_NORMAL,
|
||||
REGULATOR_STATUS_IDLE,
|
||||
REGULATOR_STATUS_STANDBY,
|
||||
};
|
||||
|
||||
/**
|
||||
* struct regulator_ops - regulator operations.
|
||||
*
|
||||
|
@ -72,6 +83,12 @@ struct regulator_ops {
|
|||
int (*set_mode) (struct regulator_dev *, unsigned int mode);
|
||||
unsigned int (*get_mode) (struct regulator_dev *);
|
||||
|
||||
/* report regulator status ... most other accessors report
|
||||
* control inputs, this reports results of combining inputs
|
||||
* from Linux (and other sources) with the actual load.
|
||||
*/
|
||||
int (*get_status)(struct regulator_dev *);
|
||||
|
||||
/* get most efficient regulator operating mode for load */
|
||||
unsigned int (*get_optimum_mode) (struct regulator_dev *, int input_uV,
|
||||
int output_uV, int load_uA);
|
||||
|
|