i2c: cadence: Check for errata condition involving master receive
Cadence I2C controller has the following bugs: - completion indication is not given to the driver at the end of a read/receive transfer with HOLD bit set. - Invalid read transaction are generated on the bus when HW timeout condition occurs with HOLD bit set. As a result of the above, if a set of messages to be transferred with repeated start includes any message following a read message, completion is never indicated and timeout occurs. Hence a check is implemented to return -EOPNOTSUPP for such sequences. Signed-off-by: Harini Katakam <harinik@xilinx.com> Signed-off-by: Vishnu Motghare <vishnum@xilinx.com> [wsa: fixed some whitespaces] Signed-off-by: Wolfram Sang <wsa@the-dreams.de>
This commit is contained in:
Родитель
ef2829144d
Коммит
8a86c3aee0
|
@ -545,6 +545,20 @@ static int cdns_i2c_master_xfer(struct i2c_adapter *adap, struct i2c_msg *msgs,
|
|||
* processed with a repeated start.
|
||||
*/
|
||||
if (num > 1) {
|
||||
/*
|
||||
* This controller does not give completion interrupt after a
|
||||
* master receive message if HOLD bit is set (repeated start),
|
||||
* resulting in SW timeout. Hence, if a receive message is
|
||||
* followed by any other message, an error is returned
|
||||
* indicating that this sequence is not supported.
|
||||
*/
|
||||
for (count = 0; count < num - 1; count++) {
|
||||
if (msgs[count].flags & I2C_M_RD) {
|
||||
dev_warn(adap->dev.parent,
|
||||
"Can't do repeated start after a receive message\n");
|
||||
return -EOPNOTSUPP;
|
||||
}
|
||||
}
|
||||
id->bus_hold_flag = 1;
|
||||
reg = cdns_i2c_readreg(CDNS_I2C_CR_OFFSET);
|
||||
reg |= CDNS_I2C_CR_HOLD;
|
||||
|
|
Загрузка…
Ссылка в новой задаче