s390/dasd: fix wrongly assigned configuration data
We store per path and per device configuration data to identify the path or device correctly. The per path configuration data might get mixed up if the original request gets into error recovery and is started with a random path mask. This would lead to a wrong identification of a path in case of a CUIR event for example. Fix by copying the path mask from the original request to the error recovery request in case it is a path verification request. Signed-off-by: Stefan Haberland <sth@linux.vnet.ibm.com> Reviewed-by: Jan Hoeppner <hoeppner@linux.vnet.ibm.com> Signed-off-by: Martin Schwidefsky <schwidefsky@de.ibm.com>
This commit is contained in:
Родитель
9f37e79754
Коммит
8a9bd4f8eb
|
@ -2803,6 +2803,16 @@ dasd_3990_erp_action(struct dasd_ccw_req * cqr)
|
|||
erp = dasd_3990_erp_handle_match_erp(cqr, erp);
|
||||
}
|
||||
|
||||
|
||||
/*
|
||||
* For path verification work we need to stick with the path that was
|
||||
* originally chosen so that the per path configuration data is
|
||||
* assigned correctly.
|
||||
*/
|
||||
if (test_bit(DASD_CQR_VERIFY_PATH, &erp->flags) && cqr->lpm) {
|
||||
erp->lpm = cqr->lpm;
|
||||
}
|
||||
|
||||
if (device->features & DASD_FEATURE_ERPLOG) {
|
||||
/* print current erp_chain */
|
||||
dev_err(&device->cdev->dev,
|
||||
|
|
Загрузка…